IBM XT/AT COMPATIBLE, BI-DIRECTIONAL  
AND EPP MODES  
BIT 3 nERR - nERROR  
The level on the nERROR input is read by the  
CPU as bit 3 of the Printer Status Register. A  
logic 0 means an error has been detected; a  
logic 1 means no error has been detected.  
DATA PORT  
ADDRESS OFFSET = 00H  
BIT 4 SLCT - PRINTER SELECTED STATUS  
The level on the SLCT input is read by the CPU  
as bit 4 of the Printer Status Register. A logic 1  
means the printer is on line; a logic 0 means it is  
not selected.  
The Data Port is located at an offset of '00H'  
from the base address. The data register is  
cleared at initialization by RESET. During a  
WRITE operation, the Data Register latches the  
contents of the data bus with the rising edge of  
the nIOW input. The contents of this register  
are buffered (non inverting) and output onto the  
PD0 - PD7 ports. During a READ operation in  
SPP mode, PD0 - PD7 ports are buffered (not  
latched) and output to the host CPU.  
BIT 5 PE - PAPER END  
The level on the PE input is read by the CPU as  
bit 5 of the Printer Status Register. A logic 1  
indicates a paper end; a logic 0 indicates the  
presence of paper.  
STATUS PORT  
ADDRESS OFFSET = 01H  
BIT 6 nACK - nACKNOWLEDGE  
The level on the nACK input is read by the CPU  
as bit 6 of the Printer Status Register. A logic 0  
means that the printer has received a character  
and can now accept another. A logic 1 means  
that it is still processing the last character or has  
not received the data.  
The Status Port is located at an offset of '01H'  
from the base address. The contents of this  
register are latched for the duration of an nIOR  
read cycle. The bits of the Status Port are  
defined as follows:  
BIT 7 nBUSY - nBUSY  
BIT 0 TMOUT - TIME OUT  
The complement of the level on the BUSY input  
is read by the CPU as bit 7 of the Printer Status  
Register. A logic 0 in this bit means that the  
printer is busy and cannot accept a new  
character. A logic 1 means that it is ready to  
accept the next character.  
This bit is valid in EPP mode only and indicates  
that a 10 usec time out has occurred on the  
EPP bus. A logic O means that no time out  
error has occurred; a logic 1 means that a time  
out error has been detected. This bit is cleared  
by a RESET. Writing a one to this bit clears the  
time out status bit. On a write, this bit is self  
clearing and does not require a write of a zero.  
Writing a zero to this bit has no effect.  
CONTROL PORT  
ADDRESS OFFSET = 02H  
The Control Port is located at an offset of '02H'  
from the base address. The Control Register is  
initialized by the RESET input, bits 0 to 5 only  
being affected; bits 6 and 7 are hard wired low.  
BITS 1, 2 - are not implemented as register bits,  
during a read of the Printer Status Register  
these bits are a low level.  