欢迎访问ic37.com |
会员登录 免费注册
发布采购

FDC37B72X_07 参数 Datasheet PDF下载

FDC37B72X_07图片预览
型号: FDC37B72X_07
PDF下载: 下载PDF文件 查看货源
内容描述: 128引脚增强型超级I / O控制器,支持ACPI [128 Pin Enhanced Super I/O Controller with ACPI Support]
分类和应用: 控制器
文件页数/大小: 238 页 / 816 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号FDC37B72X_07的Datasheet PDF文件第84页浏览型号FDC37B72X_07的Datasheet PDF文件第85页浏览型号FDC37B72X_07的Datasheet PDF文件第86页浏览型号FDC37B72X_07的Datasheet PDF文件第87页浏览型号FDC37B72X_07的Datasheet PDF文件第89页浏览型号FDC37B72X_07的Datasheet PDF文件第90页浏览型号FDC37B72X_07的Datasheet PDF文件第91页浏览型号FDC37B72X_07的Datasheet PDF文件第92页  
The level on the SLCT input is read by the CPU as  
bit 4 of the Printer Status Register. A logic 1  
means the printer is on line; a logic 0 means it is  
not selected.  
IBM XT/AT COMPATIBLE, BI-  
DIRECTIONAL AND EPP MODES  
DATA PORT  
ADDRESS OFFSET = 00H  
BIT 5 PE - PAPER END  
The level on the PE input is read by the CPU as bit  
5 of the Printer Status Register. A logic 1  
indicates a paper end; a logic 0 indicates the  
presence of paper.  
The Data Port is located at an offset of '00H' from  
the base address. The data register is cleared at  
initialization by RESET.  
During a WRITE  
operation, the Data Register latches the contents  
of the data bus with the rising edge of the nIOW  
input. The contents of this register are buffered  
(non inverting) and output onto the PD0 - PD7  
ports. During a READ operation in SPP mode,  
PD0 - PD7 ports are buffered (not latched) and  
output to the host CPU.  
BIT 6 nACK - nACKNOWLEDGE  
The level on the nACK input is read by the CPU as  
bit 6 of the Printer Status Register. A logic 0  
means that the printer has received a character  
and can now accept another. A logic 1 means that  
it is still processing the last character or has not  
received the data.  
STATUS PORT  
ADDRESS OFFSET = 01H  
BIT 7 nBUSY - nBUSY  
The complement of the level on the BUSY input is  
read by the CPU as bit 7 of the Printer Status  
Register. A logic 0 in this bit means that the  
printer is busy and cannot accept a new character.  
A logic 1 means that it is ready to accept the next  
character.  
The Status Port is located at an offset of '01H'  
from the base address. The contents of this  
register are latched for the duration of an nIOR  
read cycle. The bits of the Status Port are defined  
as follows:  
BIT 0 TMOUT - TIME OUT  
CONTROL PORT  
ADDRESS OFFSET = 02H  
This bit is valid in EPP mode only and indicates  
that a 10 usec time out has occurred on the EPP  
bus. A logic O means that no time out error has  
occurred; a logic 1 means that a time out error has  
been detected. This bit is cleared by a RESET.  
Writing a one to this bit clears the time out status  
bit. On a write, this bit is self clearing and does not  
require a write of a zero. Writing a zero to this bit  
has no effect.  
The Control Port is located at an offset of '02H'  
from the base address. The Control Register is  
initialized by the RESET input, bits 0 to 5 only  
being affected; bits 6 and 7 are hard wired low.  
BIT 0 STROBE - STROBE  
This bit is inverted and output onto the nSTROBE  
output.  
BITS 1, 2 - are not implemented as register bits,  
during a read of the Printer Status Register these  
bits are a low level.  
BIT 1 AUTOFD - AUTOFEED  
This bit is inverted and output onto the nAUTOFD  
output. A logic 1 causes the printer to generate a  
line feed after each line is printed. A logic 0 means  
no autofeed.  
BIT 3 nERR - nERROR  
The level on the nERROR input is read by the  
CPU as bit 3 of the Printer Status Register.  
A
logic 0 means an error has been detected; a logic  
1 means no error has been detected.  
BIT 4 SLCT - PRINTER SELECTED STATUS  
88  
 复制成功!