RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown  
Datasheet  
Table A.2 Look Up Table Example #1 Configuration  
ADDR  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
SETTING  
USE_  
DTS_F1  
USE_  
DTS_F2  
LUT_  
LOCK  
RPM /  
PWM  
PUSH1_  
CFG  
TEMP1_  
CFG  
TEMP3_ TEMP4_  
LUT  
Configuration  
CFG  
0
CFG  
0
50h  
C0h  
0
0
1
1
0
0
A.1.1  
LUT Configuration Bit Description  
Bit 7 - USE_DTS_F1 = ‘0b’ tells the circuitry that the Forced Temperature 1 register data is not in DTS  
format.  
Bit 6 - USE_DTS_F2 = ‘0b’ tells the circuitry that the Forced Temperature 2 register data is not in DTS  
format.  
Bit 5 - LUT_LOCK = ‘1b’ tells the circuitry that the LUT is programmed and is active. This bit must be  
set for the LUT to function.  
Bit 4 - RPM / PWM = ‘1b’ tells the Look Up Table that the FSC algorithm is not used and that the LUT  
target values will be PWM drive settings instead of TACH Target settings.  
Bit 3 - PUSH1_CFG = ‘0b’ tells the circuitry that the LUT should referenced the Forced Temperature  
data instead of the PWM Input Duty Cycle data. This is the default setting.  
Bit 2 - TEMP1_CFG = ‘0b’ tells the LUT to reference the External Diode 1 data instead of Forced  
Temperature 1 data. This is the default setting.  
Bit 1 - TEMP3_CFG = ‘0b’ tells the LUT to reference the External Diode 3 data instead of Forced  
Temperature 1 data. This is the default setting.  
Bit 0 - TEMP4_CFG = ‘0b’ tells the LUT to reference the Internal Diode data instead of Forced  
Temperature 2 data. This is the default setting.  
Table A.3 Fan Speed Control Table Example #1  
EXTERNAL  
FAN  
SPEED  
STEP #  
EXTERNALDIODE  
1 TEMPERATURE  
(CPU)  
DIODE 2  
TEMPERATURE  
(GPU)  
EXTERNAL DIODE  
3 TEMPERATURE  
(SKIN)  
INTERNAL DIODE  
TEMPERATURE  
(AMBIENT)  
PWM  
SETTINGS  
1
2
3
4
5
6
7
8
35oC  
40oC  
50oC  
60oC  
70oC  
80oC  
90oC  
100oC  
60oC  
70oC  
75oC  
80oC  
85oC  
90oC  
95oC  
100oC  
30oC  
35oC  
40oC  
45oC  
50oC  
55oC  
60oC  
65oC  
40oC  
45oC  
50oC  
55oC  
60oC  
65oC  
70oC  
75oC  
0%  
30%  
40%  
50%  
60%  
70%  
80%  
100%  
Note: The values shown in Table A.3 are example settings. All the cells in the look-up table are  
programmable via SMBus.  
SMSC EMC2113  
Revision 1.2 (10-08-09)  
DATA8S1HEET  
 复制成功!