RPM-Based Fan Controller with Multiple Temperature Zones & Hardware Thermal Shutdown  
Datasheet  
7.30  
Valid TACH Count Register  
Table 7.47 Valid TACH Count Register  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Valid TACH  
Count  
49h  
R/W  
4096  
2048  
1024  
512  
256  
128  
64  
32  
F5h  
The Valid TACH Count Register store the maximum TACH Reading Register value to indicate that the  
the fan is spinning properly. The value is referenced at the end of the Spin Up Routine to determine  
if the fan has started operating and decide if the device needs to retry.  
See Equation [5] for translating the count to an RPM.  
If the TACH Reading Register value exceeds the Valid TACH Count Register (indicating that the Fan  
RPM is below the threshold set by this count), then a stalled fan is detected. In this condition, the  
algorithm will automatically begin its Spin Up Routine.  
APPLICATION NOTE: The automatic invoking of the Spin Up Routine only applies if the Fan Speed Control  
Algorithm is used. If the FSC is disabled, then the device will only invoke the Spin Up Routine  
when the PWM setting changes from 00h.  
If a TACH Target setting is set above the Valid TACH Count setting, then that setting will be ignored  
and the algorithm will use the current fan drive setting.  
The Valid TACH Count Register is software locked.  
7.31  
Fan Drive Fail Band Registers  
Table 7.48 Fan Drive Fail Band Registers  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Fan Drive  
Fail Band  
Low Byte  
4Ah  
R/W  
16  
8
4
2
1
-
-
-
00h  
Fan Drive  
Fail Band  
High Byte  
4Bh  
R/W  
4096 2048 1024  
512  
256  
128  
64  
32  
00h  
The Fan Drive Fail Band Registers store the number of tach counts used by the Fan Drive Fail  
detection circuitry. This circuitry is activated when the fan drive setting high byte is at FFh. When it is  
enabled, the actual measured fan speed is compared against the target fan speed.  
This circuitry is used to indicate that the target fan speed at full drive is higher than the fan is actually  
capable of reaching. If the measured fan speed does not exceed the target fan speed minus the Fan  
Drive Fail Band Register settings for a period of time longer than set by the DRIVE_FAIL_CNTx[1:0]  
bits then the DRIVE_FAIL status bit will be set and an interrupt generated.  
SMSC EMC2113  
Revision 1.2 (10-08-09)  
DATA6S5HEET  