欢迎访问ic37.com |
会员登录 免费注册
发布采购

EMC2101-ACZL-TR 参数 Datasheet PDF下载

EMC2101-ACZL-TR图片预览
型号: EMC2101-ACZL-TR
PDF下载: 下载PDF文件 查看货源
内容描述: SMBus的风扇控制为1° C的精密温度监控 [SMBus Fan Control with 1∑C Accurate Temperature Monitoring]
分类和应用: 风扇传感器换能器温度传感器输出元件监控PC
文件页数/大小: 55 页 / 1171 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号EMC2101-ACZL-TR的Datasheet PDF文件第40页浏览型号EMC2101-ACZL-TR的Datasheet PDF文件第41页浏览型号EMC2101-ACZL-TR的Datasheet PDF文件第42页浏览型号EMC2101-ACZL-TR的Datasheet PDF文件第43页浏览型号EMC2101-ACZL-TR的Datasheet PDF文件第45页浏览型号EMC2101-ACZL-TR的Datasheet PDF文件第46页浏览型号EMC2101-ACZL-TR的Datasheet PDF文件第47页浏览型号EMC2101-ACZL-TR的Datasheet PDF文件第48页  
SMBus Fan Control with 1°C Accurate Temperature Monitoring  
Datasheet  
Where:  
PWM_F is the setting of the PWM  
Frequency register (4Dh)  
360k  
--------------------------------  
1
5806  
FREQ  
-----------------  
-----------------  
PWM_D =  
×
=
[5]  
PWM_D is the setting of the PWM  
Frequency Divide Register (4Eh)  
2 × PWM_F  
FREQ  
FREQ is the desired PWM  
Frequency  
Maximum resolution is achieved by setting the PWM Frequency Register to 1Fh. With maximum  
resolution, the desired PWM frequency can be achieved by adjusting the PWM Frequency Divide  
Register setting (PWM_D[7:0]) as shown in Table 6.26.  
For example, if the user desires a 30Hz PWM frequency with maximum PWM resolution, then the  
PWM_F[4:0] bits should be set at 1Fh (31d) and the the PWM_D bits should be set at C1h (193d).  
Table 6.26 Examples of Fan PWM Frequency with Maximum Resolution  
PWM_F[4:0] = 1Fh  
EFFECTIVE  
DUTY CYCLE  
(AT 50%  
EFFECTIVE  
DUTY CYCLE  
(AT 75%  
EFFECTIVE  
RESOLUTION  
(%)  
FAN_SETTING  
TO GET 75%  
DUTY CYCLE  
PWM_D[7:0]  
SETTING  
EFFECTIVE PWM  
FREQUENCY (HZ)  
FAN_SETTING) FAN_SETTING)  
01h  
11h  
20h  
47h  
C0  
1.61  
1.61  
1.61  
1.61  
1.61  
1.61  
1.61  
51.6%  
51.6%  
51.6%  
51.6%  
51.6%  
51.6%  
51.6%  
77.4%  
77.4%  
77.4%  
77.4%  
77.4%  
77.4%  
77.4%  
2Eh (74.2%)  
2Eh (74.2%)  
2Eh (74.2%)  
2Eh (74.2%)  
2Eh (74.2%)  
2Eh (74.2%)  
2Eh (74.2%)  
5806.5  
341.6  
181.5  
81.8  
30.2  
C1  
30.0  
FFh  
22.7  
6.21  
Fan Control Look-Up Table Hysteresis Register  
Table 6.27 Look Up Table Hysteresis Register  
ADDR.  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Fan Control Look-  
Up Table Hysteresis  
04h  
(4°C)  
4Fh  
R/W  
-
-
-
16  
8
4
2
1
The Fan Control Look-Up Table Hysteresis Register determines the amount of hysteresis applied to  
the temperature inputs of the fan control Fan Control Look-Up Table. See Section 5.6.4.  
Revision 2.53 (03-13-07)  
SMSC EMC2101  
DATA4S4HEET