欢迎访问ic37.com |
会员登录 免费注册
发布采购

EMC1412-2-ACZL-TR 参数 Datasheet PDF下载

EMC1412-2-ACZL-TR图片预览
型号: EMC1412-2-ACZL-TR
PDF下载: 下载PDF文件 查看货源
内容描述: 多通道1温度传感器,带有beta补偿 [Multiple Channel 1 Temperature Sensor with Beta Compensation]
分类和应用: 传感器换能器温度传感器输出元件
文件页数/大小: 47 页 / 789 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号EMC1412-2-ACZL-TR的Datasheet PDF文件第19页浏览型号EMC1412-2-ACZL-TR的Datasheet PDF文件第20页浏览型号EMC1412-2-ACZL-TR的Datasheet PDF文件第21页浏览型号EMC1412-2-ACZL-TR的Datasheet PDF文件第22页浏览型号EMC1412-2-ACZL-TR的Datasheet PDF文件第24页浏览型号EMC1412-2-ACZL-TR的Datasheet PDF文件第25页浏览型号EMC1412-2-ACZL-TR的Datasheet PDF文件第26页浏览型号EMC1412-2-ACZL-TR的Datasheet PDF文件第27页  
Multiple Channel 1°C Temperature Sensor with Beta Compensation  
Datasheet  
6.8  
Temperature Measurement Results and Data  
The temperature measurement results are stored in the internal and external temperature registers.  
These are then compared with the values stored in the high and low limit registers. Both external and  
internal temperature measurements are stored in 11-bit format with the eight (8) most significant bits  
stored in a high byte register and the three (3) least significant bits stored in the three (3) MSB  
positions of the low byte register. All other bits of the low byte register are set to zero.  
The EMC1412 has two selectable temperature ranges. The default range is from 0°C to +127°C and  
the temperature is represented as binary number able to report a temperature from 0°C to +127.875°C  
in 0.125°C steps.  
The extended range is an extended temperature range from -64°C to +191°C. The data format is a  
binary number offset by 64°C. The extended range is used to measure temperature diodes with a large  
known offset (such as AMD processor diodes) where the diode temperature plus the offset would be  
equivalent to a temperature higher than +127°C.  
Table 6.2 shows the default and extended range formats.  
Table 6.2 Temperature Data Format  
TEMPERATURE (°C)  
DEFAULT RANGE 0°C TO 127°C  
EXTENDED RANGE -64°C TO 191°C  
Diode Fault  
-64  
000 0000 0000  
000 0000 0000  
000 0000 0000  
000 0000 0000  
Note 6.2  
-1  
0
000 0000 0000  
001 1111 1000  
010 0000 0000  
000 0000 0000  
Note 6.1  
0.125  
1
000 0000 0001  
000 0000 1000  
010 0000 0000  
010 0000 1000  
011 1111 1000  
011 1111 1111  
010 0000 0001  
010 0000 1000  
100 0000 0000  
100 0000 1000  
101 1111 1000  
101 1111 1111  
110 0000 0000  
64  
65  
127  
127.875  
128  
011 1111 1111  
Note 6.3  
190  
011 1111 1111  
011 1111 1111  
011 1111 1111  
111 1111 0000  
111 1111 1000  
191  
>= 191.875  
111 1111 1111  
Note 6.4  
Note 6.1 In default mode, all temperatures < 0°C will be reported as 0°C.  
Note 6.2 In the extended range, all temperatures < -64°C will be reported as -64°C.  
Note 6.3 For the default range, all temperatures > +127.875°C will be reported as +127.875°C.  
Note 6.4 For the extended range, all temperatures > +191.875°C will be reported as +191.875°C.  
SMSC EMC1412  
Revision 1.41 (02-23-12)  
DATA2S3HEET