 浏览型号EMC1023-3-ACZB-TR的Datasheet PDF文件第10页浏览型号EMC1023-3-ACZB-TR的Datasheet PDF文件第11页浏览型号EMC1023-3-ACZB-TR的Datasheet PDF文件第12页浏览型号EMC1023-3-ACZB-TR的Datasheet PDF文件第13页浏览型号EMC1023-3-ACZB-TR的Datasheet PDF文件第15页浏览型号EMC1023-3-ACZB-TR的Datasheet PDF文件第16页浏览型号EMC1023-3-ACZB-TR的Datasheet PDF文件第17页浏览型号EMC1023-3-ACZB-TR的Datasheet PDF文件第18页  
1°C Triple Temperature Sensor with Resistance Error Correction  
Datasheet  
4.9  
Configuration Register  
Table 4.7 Configuration Register  
REGISTER  
Configuration  
BIT 7  
BIT 6  
BIT 5  
BIT 4  
BIT 3  
BIT 2  
BIT 1  
BIT 0  
DEF  
-
nRun/Stop  
-
-
-
CR2  
CR1  
CR0  
47h  
Bits 0 through bit 2 of the configuration register set the ADC conversion rate of the part. See Table 4.8,  
“Configuration Register, Conversion Rate,” on page 14  
Table 4.8 Configuration Register, Conversion Rate  
CR2, CR1, CR0  
CONVERSION RATE  
000  
001  
010  
011  
100  
101  
110  
111  
Reserved  
Reserved  
Reserved  
1 Conversions per second  
2 Conversions per second  
4 Conversions per second  
8 Conversions per second  
16 Conversions per second  
A conversion for all 3 temperature readings takes about 60ms. Therefore, the maximum conversion  
rate, equals 16 conversions per second.  
Bits 6 set of the Configuration Register sets the power mode of the part:  
Table 4.9 Configuration Registers Data Format  
NRUN/STOP  
DESCRIPTION  
0
1
Run Mode  
Standby Mode  
In Run Mode, the EMC1023 will operate at the preset conversion rate. In Standby Mode, the part is  
powered down to minimize current consumption. The SMBus is fully operational in either mode. In  
Standby Mode, a WRITE command to the One Shot register will trigger a one time conversion of the  
3 temperature monitors. After the part finishes the conversion, it will go back to Standby Mode. The  
host can now read the updated temperature information.  
Revision 1.2 (04-15-05)  
SMSC EMC1023  