欢迎访问ic37.com |
会员登录 免费注册
发布采购

COM20019IP 参数 Datasheet PDF下载

COM20019IP图片预览
型号: COM20019IP
PDF下载: 下载PDF文件 查看货源
内容描述: 低成本ARCNET ( ANSI 878.1 )控制器2K ×8板载RAM [Low Cost ARCNET (ANSI 878.1) Controller with 2K x 8 On-Board RAM]
分类和应用: 微控制器和处理器串行IO控制器通信控制器外围集成电路光电二极管数据传输局域网时钟
文件页数/大小: 81 页 / 455 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号COM20019IP的Datasheet PDF文件第6页浏览型号COM20019IP的Datasheet PDF文件第7页浏览型号COM20019IP的Datasheet PDF文件第8页浏览型号COM20019IP的Datasheet PDF文件第9页浏览型号COM20019IP的Datasheet PDF文件第11页浏览型号COM20019IP的Datasheet PDF文件第12页浏览型号COM20019IP的Datasheet PDF文件第13页浏览型号COM20019IP的Datasheet PDF文件第14页  
NETWORK RECONFIGURATION  
Each COM20019 on the network will finally have  
saved a NID value equal to the ID of the  
COM20019 that it released control to. At this  
point, control is passed directly from one node to  
the next with no wasted INVITATIONS TO  
TRANSMIT being sent to ID's not on the network,  
until the next NETWORK RECONFIGURATION  
occurs. When a node is powered off, the previous  
node attempts to pass the token to it by issuing an  
INVITATION TO TRANSMIT. Since this node  
does not respond, the previous node times out  
A significant advantage of the COM20019 is its  
ability to adapt to changes on the network.  
Whenever a new node is activated or deactivated,  
a NETWORK RECONFIGURATION is performed.  
When a new COM20019 is turned on (creating a  
new active node on the network), or if the  
COM20019 has not received an INVITATION TO  
TRANSMIT for 6.72S, or if a software reset  
occurs, the COM20019 causes a NETWORK  
RECONFIGURATION  
by  
sending  
a
and transmits another  
INVITATION TO  
RECONFIGURE BURST consisting of eight  
marks and one space repeated 765 times. The  
purpose of this burst is to terminate all activity on  
the network. Since this burst is longer than any  
other type of transmission, the burst will interfere  
TRANSMIT to an incremented ID and eventually a  
response will be received.  
The NETWORK RECONFIGURATION time  
depends on the number of nodes in the network,  
the propagation delay between nodes, and the  
highest ID number on the network, but is typically  
within the range of 192 to 488 mS.  
with the next INVITATION  
TO TRANSMIT,  
destroy the token and keep any other node from  
assuming control of the line.  
When any COM20019 senses an idle line for  
greater than 656 S, which occurs only when the  
token Is lost, each COM20019 starts an internal  
timeout equal to 1.168mS times the quantity 255  
minus its own ID. The COM20019 starts network  
reconfiguration by sending an invitation to transmit  
first to itself and then to all other nodes by  
decrementing the destination Node ID. If the  
timeout expires with no line activity, the  
COM20019 starts sending INVITATION TO  
TRANSMIT with the Destination ID (DID) equal to  
the currently stored NID. Within a given network,  
only one COM20019 will timeout (the one with the  
highest ID number). After sending the  
INVITATION TO TRANSMIT, the COM20019  
waits for activity on the line. If there is no activity  
for 597.6 S, the COM20019 increments the NID  
value and transmits another INVITATION TO  
TRANSMIT using the NID equal to the DID. If  
activity appears before the 597.6 S timeout  
expires, the COM20019 releases control of the  
line. During NETWORK RECONFIGURATION,  
INVITATIONS TO TRANSMIT are sent to all NIDs  
(1-255).  
BROADCAST MESSAGES  
Broadcasting gives a particular node the ability to  
transmit a data packet to all nodes on the network  
simultaneously. ID zero is reserved for this  
feature and no node on the network can be  
assigned ID zero. To broadcast a message, the  
transmitting node's processor simply loads the  
RAM buffer with the data packet and sets the DID  
equal to zero. Figure 4 illustrates the position of  
each byte in the packet with the DID residing at  
address 0X01 or 1 Hex of the current page  
selected in the "Enable Transmit from Page fnn"  
command. Each individual node has the ability to  
ignore broadcast messages by setting the most  
significant bit of the "Enable Receive to Page fnn"  
command to a logic "0".  
EXTENDED TIMEOUT FUNCTION  
There are three timeouts associated with the  
COM20019 operation.  
The values of these  
timeouts are controlled by bits 3 and 4 of the  
Configuration Register and bit 5 of the Setup 1  
Register.  
10  
DISCONTINUED DATASHEET