 浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第37页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第38页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第39页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第40页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第42页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第43页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第44页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第45页  
5 and 6 Channel Capacitive Touch Sensor  
Datasheet  
Bits 2 - 0 - CAL_CFG[2:0] - Determines the update time and number of samples of the automatic re-  
calibration routine. The settings applies to all sensors universally (though individual sensors can be  
configured to support re-calibration - see Section 5.11).  
Table 5.25 CAL_CFG Bit Decode  
CAL_CFG[2:0]  
RECALIBRATION  
SAMPLES (SEE  
UPDATE TIME (SEE  
2
1
0
Note 5.1)  
Note 5.2)  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
16  
32  
16  
32  
64  
64  
256  
256  
256  
256  
256  
256 (default)  
1024  
2048  
4096  
7936  
Note 5.1 Recalibration Samples refers to the number of samples that are measured and averaged  
before the Base Count is updated however does not control the base count update period.  
Once this target number of update cycles is reached, the device may wait additional time  
as determined by the Update Time before the base count is updated as determiend by the  
settings.  
Note 5.2 Update Time refers to the amount of time (in polling cycle periods) that elapses before the  
Base Count is updated. For those settings that have the Update Time greater than the  
Recalibration Samples value, the device will wait (and continue to average the updated  
base count) until the Update Time has elapsed before the base count is updated.  
5.16 Sensor Threshold Registers  
Table 5.26 Sensor Threshold Registers  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Sensor 1  
Threshold  
30h  
R/W  
-
64  
32  
16  
8
4
2
1
40h  
Sensor 2  
Threshold  
31h  
32h  
33h  
34h  
35h  
R/W  
R/W  
R/W  
R/W  
R/W  
-
-
-
-
-
64  
64  
64  
64  
64  
32  
32  
32  
32  
32  
16  
16  
16  
16  
16  
8
8
8
8
8
4
4
4
4
4
2
2
2
2
2
1
1
1
1
1
40h  
40h  
40h  
40h  
40h  
Sensor 3  
Threshold  
Sensor 4  
Threshold  
Sensor 5  
Threshold  
Sensor 6  
Threshold  
SMSC CAP1005 / CAP1006  
Revision 1.1 (08-05-09)  
DATA4S1HEET