欢迎访问ic37.com |
会员登录 免费注册
发布采购

CAP1006-2-AIA-TR 参数 Datasheet PDF下载

CAP1006-2-AIA-TR图片预览
型号: CAP1006-2-AIA-TR
PDF下载: 下载PDF文件 查看货源
内容描述: 5和6通道电容式触摸传感器 [5 and 6 Channel Capacitive Touch Sensor]
分类和应用: 模拟IC传感器信号电路
文件页数/大小: 53 页 / 736 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第32页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第33页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第34页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第35页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第37页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第38页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第39页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第40页  
5 and 6 Channel Capacitive Touch Sensor  
Datasheet  
Table 5.13 RPT_RATE Bit Decode (continued)  
RPT_RATE[3:0] OR M_PRESS[3:0]  
INTERRUPT REPEAT RATE  
OR M_PRESS TIME  
3
2
1
0
0
1
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
1
0
0
1
1
0
0
1
1
1
0
1
0
1
0
1
0
1
280ms  
315ms  
350ms  
385ms  
420ms  
455ms  
490ms  
525ms  
560ms  
5.9  
Sensor Configuration 2 Register  
Table 5.14 Sensor Configuration 2 Register  
ADDR  
23h  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Sensor  
Configuration 2  
R/W  
-
-
-
-
M_PRESS[3:0]  
07h  
Bits 3- 0 - M_PRESS[3:0] - (default 0111b) - Determines the minimum amount of time that sensors  
configured to use auto repeat must detect a sensor touch to detect a “press and hold” event. If the  
sensor detects a touch for longer than the M_PRESS[3:0] settings, then a “press and hold” event is  
detected.  
This is the maximum amount of time that sensors can detect a sensor touch to differentiate between  
a “touch” and a “press and hold”. If a sensor detects a touch for less than or equal to the  
M_PRESS[3:0] settings, then a touch event is detected.  
The resolution is 35ms the range is from 35ms to 560ms as shown in Table 5.13.  
5.10 Averaging and Sampling Configuration Register  
Table 5.15 Averaging and Sampling Configuration Register  
ADDR  
R/W  
REGISTER  
B7  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
DEFAULT  
Averaging and  
Sampling Config  
SAMP_  
TIME  
CYCLE_TIME  
[1:0]  
24h  
R/W  
AVG[2:0]  
1Dh  
The Averaging and Sampling Configuration register controls the number of samples taken and the total  
sensor cycle time for all active sensors while the device is functioning normally.  
Bits 5 - 3 - AVG[2:0] - Determines the number of samples that are taken for all active channels during  
the sensor cycle as shown in Table 5.16. All samples are taken consecutively on the same channel  
Revision 1.1 (08-05-09)  
SMSC CAP1005 / CAP1006  
DATA3S6HEET