欢迎访问ic37.com |
会员登录 免费注册
发布采购

CAP1006-2-AIA-TR 参数 Datasheet PDF下载

CAP1006-2-AIA-TR图片预览
型号: CAP1006-2-AIA-TR
PDF下载: 下载PDF文件 查看货源
内容描述: 5和6通道电容式触摸传感器 [5 and 6 Channel Capacitive Touch Sensor]
分类和应用: 模拟IC传感器信号电路
文件页数/大小: 53 页 / 736 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第18页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第19页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第20页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第21页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第23页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第24页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第25页浏览型号CAP1006-2-AIA-TR的Datasheet PDF文件第26页  
5 and 6 Channel Capacitive Touch Sensor  
Datasheet  
1. Register Read Address  
updatedtoCurrent SPI Read  
Address pointer.  
2. Register Read Address  
incremented = current address  
pointer +1 – end result =  
register address pointer doesn’t  
change  
1. Register Read Address  
incremented = current address  
pointer + 1  
1. Register Read Address  
updatedtoCurrent SPI Read  
Address pointer  
SPI_CS#  
SPI_MISO  
‘0’  
‘1’  
‘1’  
‘1’  
‘1’  
‘1’  
‘1’  
‘1’  
‘0’  
‘1’  
‘1’  
‘1’  
‘1’  
‘1’  
‘1’  
‘1’  
XXh  
Read Command – 7Fh  
Subsequent Read Commands – 7Fh  
Master SPDOUT  
SPI_MOSI  
Data at previously set register address = current  
Data at previously set register address = current  
address pointer (SPI)  
Data at previously set register address = current  
address pointer (SPI)  
address pointer  
Master Drives  
Slave Drives  
1. Output buffer transmitted=  
data at previous address  
pointer + 1 = current address  
pointer  
Register Data loaded into  
Output buffer = data at current  
address pointer + 1  
1. Register data loaded into  
output buffer = data at current  
address pointer  
1. Register data loaded into  
output buffer = data at current  
address pointer  
1. SPI Read Address  
Incremented = new current  
address pointer  
2. Register Read Address  
Incremented = current address 1. Output buffer transmitted =  
1. Output buffer transmitted =  
data at current address pointer  
+ 1  
2. Flag set to increment SPI  
Read Address at end of next 8  
clocks  
1. Output buffer transmitted =  
data at current address pointer  
+ 1  
2. Flagset toincrement SPI  
Read Address at end of next 8  
clocks  
pointer +1  
data at previous register  
address pointer + 1 = current  
address pointer  
Figure 3.6 SPI Read Command - Normal Mode - Full  
3.6  
BC-Link Interface (CAP1006-2 only)  
The BC-Link is a proprietary bus developed to allow communication between a host controller device  
to a companion device. This device uses this serial bus to read and write registers and for interrupt  
processing. The interface uses a data port concept, where the base interface has an address register,  
data register and a control register, defined in the SMSC’s 8051’s SFR space.  
Refer to documentation for the BC-Link comptabile host controller for details on how to access the  
CAP1006 via the BC-Link Interface.  
Revision 1.1 (08-05-09)  
SMSC CAP1005 / CAP1006  
DATA2S2HEET