GENERAL SPECIFICATIONS
Hold-up time
Efficiency
isolation voltage
Switching frequency
Safety Approvals
Maximum weight
120 Vac, 60 Hz
120 Vac 900 W output
input to ouput
input to ground
fixed
>35 ms at 900 Watts output
>84 %
4000 Vac
1800 Vac
70 KHz, +/- 10 KHz
UL/EN/IEC 60601-1 CSA22.2 No.60601-1
2 kg (4.4 lbs)
MODEL NUMBER
GPMP900-24
GPMP900-28
GPMP900-36
GPMP900-48
All Models Aux. output
NOTES
1. Integral forced air cooling
Output
24 V 37.5 A
28 V 32.1 A
36 V 25.0 A
48 V 18.8 A
12.25 V 0.25 A
Peak Output
24 V 39.5 A
28 V 34.1 A
36 V 27.0 A
48 V 20.8 A
N/A
Features
+/-5% adjust
+/-5% adjust
+/-5% adjust
+/-5% adjust
N/A
Ripple (3)
<240 mV
<240 mV
<240 mV
<240 mV
<120 mV
Regulation
+/- 0.5%
+/- 0.5%
+/- 0.5%
+/- 0.5%
11.9 - 12.7 V
2. Peak rating is for 1 minute maximum 10% duty cycle
3. Noise measurent 20 MHz Bandwidth, differential mode. Measured with scope probe directly across output terminals of the power supply.
4. 12 V Auxiliary output does not shutdown with inhibit
MECHANICAL NOTES
The GPMP series is factory configured with standard connectors. Options B and T are available, Please contact factory for other connector arrange-
ments
Page 2 of 3