欢迎访问ic37.com |
会员登录 免费注册
发布采购

GPMP600 参数 Datasheet PDF下载

GPMP600图片预览
型号: GPMP600
PDF下载: 下载PDF文件 查看货源
内容描述: 环境报告:执行摘要 [ENVIRONMENTAL REPORT: EXECUTIVE SUMMARY]
分类和应用:
文件页数/大小: 12 页 / 3250 K
品牌: SLPOWER [ SL Power Electronics ]
 浏览型号GPMP600的Datasheet PDF文件第2页浏览型号GPMP600的Datasheet PDF文件第3页浏览型号GPMP600的Datasheet PDF文件第4页浏览型号GPMP600的Datasheet PDF文件第5页浏览型号GPMP600的Datasheet PDF文件第6页浏览型号GPMP600的Datasheet PDF文件第7页浏览型号GPMP600的Datasheet PDF文件第8页浏览型号GPMP600的Datasheet PDF文件第9页  
2311 STATHAM PARKWAY
OXNARD, CALIFORNIA 93033
TELEPHONE (805) 486-4565
a subsidiary of SL INDUSTRIES, INC.
ISO 9001-2000 CERTIFIED
FAX (805) 487-8911
www.condorpower.com
ENVIRONMENTAL REPORT: EXECUTIVE SUMMARY
07/15/05
FAMILY:
MODEL:
REVISION:
HALT
In order to increase the field reliability of its power supplies, Condor uses HALT (Highly Accelerated
Life Test) testing. This is a design margin test, where the test specimen is exposed to
successively higher levels of stress, until failure occurs. The failure mechanism is diagnosed,
corrected, and the process is repeated until an acceptable level of margin is achieved. An
acceptable level is usually a point where the fundamental design limit is reached, or
implementation of a fix is technically or economically unfeasible. The greater the design margin,
the less likely that a field failure will occur due to that particular stimulus.
HALT Temperature Cycling Step Stress
HALT Operating Temperature Range:
HALT Vibration Step Stress
Maximum Operating Level:
GPMP / GPHP
GPMP600-24
A
Pass
Pass
Condor Non-Operating Vibration
The product is exposed to random vibration, in order to simulate the environment encountered during
transportation. The product is exposed to 5 grms, 10-2000 hz random vibration, for 1 hour
per axis, in 3 axes. No mechanical or electrical damage is allowed.
Result:
Pass
Cold Start-up Time
The time measured, from the application of input voltage, for the unit to reach the specified output
voltage. This is measured at the specified temperature, as well as lower temperatures.
Result:
Pass
IR Imaging and Thermal Survey
The unit is photographed during operation with an imaging infrared camera to locate hot spots. The
major components, along with anything additionally identified during the IR scan, are
thermocoupled. Temperatures are measured at the maximum specified ambient temperature.
Status:
Done
Please see attached report for detail