Condor Temperature HALT Profile
100
90
80
70
60
50
40
30
20
10
0
Temp
Power
-10
-20
-30
-40
-50
0
2
4
6
8
10
12
14
16
18
20
Power Cycling: Five OFF/ON cycles (1 Min ON / 1 Min OFF) are performed at the end of each dwell.
Parameters monitored: Vin, Vout, signals as required (power good, etc.)
Pass/Fail criteria: Loss of output, or output is outside specified limit.
Random Vibration Step Stress
PSD Gsqd/Hz
350 Hz
Cum.
Overall
Grms
Time
(min:sec)
Level
Damage
10 Hz
2000 Hz
(Qual=1)
1
2
3
4
5
10:00
10:00
10:00
10:00
10:00
5
7
9
11
13
0.038
0.078
0.129
0.192
0.269
0.038
0.078
0.129
0.192
0.269
0.0012
0.0024
0.004
0.0059
0.0082
0.17
1.6
9
37
120
Parameters Monitored: Vin, Vout, signals as required (power good, etc.)
Pass/Fail criteria: Loss of output, or output is outside specified limit.
Condor HALT Random Vibration Profile
1
.1
.01
.001
X Axis
.0001
Y Axis
10
100
1000
2000
Frequency (Hz)
Z Axis