CINT1275
275W Single Output
Industrial Series
General Specifications (continued)
F1, F2: 5A, 275Vac fuses provided on all
models
120 to 150% of rating, Hiccup Mode
Input Fuses
Overload Protection
Earth Leakage
Current
Short Circuit
Protection
<750μA@264Vac, 60Hz, NC
Hiccup Mode, auto recovery.
Overvoltage
Protection
92% typical
OVP latch at 110 to 130% of output voltage
Efficiency
275W continuous, with 200 lfm airflow, 180W
convection cooled – See chart for specific
voltage model ratings.
PFC: Variable, 30kHz - 400kHz
Main Converter: Variable 30-250kHz, 65-
70kHz at full load.
Output Power
Switching Frequency
Isolation
500µS typical, return to 0.5% of nominal, 50%
load step. i/t: <0.2A/μS. Max Voltage
Deviation = 3%
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 1500Vac
Transient
Response
Operating
Temperature
-10°C to +70°C
Start Up at -40°C, full load
0.5%rms, 1% pk-pk, see chart.
See chart
Ripple and Noise
Output Voltage
Temperature
Derating
Derate output power linearly above 50°C to
50% at 70°C
Voltage
Adjustability
+/-5% from nominal (except 56V)
Not required
-40°C to +85°C
Storage Temperature
Altitude
Operating: -500 to 10,000 ft.
Non-operating: -500 to 40,000 ft.
Minimum Load
+/- 3% combined line, load and initial setting.
5% to 95%, non-condensing
Total Regulation
Relative Humidity
Operating: 0.003g/Hz, 1.5grms overall, 3
axes, 10 min/axis
Non-Operating: 0.026g2/Hz, 5.0grms overall,
3 axes, 1 hr/axis
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6
shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3
axes, 6 shocks total
Vibration
Shock
W: 3.0” x L: 5.0” x H: 1.38” (from bottom of PC
Board).
EN/CSA/UL/IEC 60950-1, 2nd Edition
Dimensions
Weight
Safety Standards
MTBF
465,000 hours, 275W load, 110Vac input,
25°C ambient
325g
Auxiliary Signals
Open collector logic signal goes and stays HIGH
100mS to 500mS after main output reaches
regulation.
Goes LOW with 5mS warning before loss of
DC output after loss of AC power.
AC Power Fail:
DC OK:
Fan Output:
Connect to inhibit pin (J201 pin 5) to output
common to inhibit the DC output.
12V @ 1A
Inhibit:
Compensates for up to 250mV drop in load
lines.
Forced Current Sharing provided for up to 5
units connected in parallel.
Remote Sense:
Current Share:
www.slpower.com
CINT1275 REV 1.2 15-JAN-13
2