DATA SHEET • CLA SERIES DIODES
Table 1. CLA Series Absolute Maximum Ratings
Parameter
Power dissipation
Symbol
Minimum
Typical
Maximum
Units
Maximum TJ ꢀ Case Temp
PDIS
W
Thermal Resistance junctionꢀtoꢀcase
Reverse voltage
VR
IF
Minimum rated breakdown voltage
V
Forward current
200
mA
qC
qC
Junction temperature
Storage temperature
TJ
–65
–65
+175
+200
TSTG
Note: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 2. CLA Series Electrical Specifications (Note 1)
(TOP = +25 qC, CJ Measured at 1 MHz, RS Measured at 500 MHz, CW Thermal Resistance for Infinite Heat Sink, Pulse Thermal Resistance
for Single 1 μs Pulse, Unless Otherwise Noted)
Minority
Carrier
Lifetime (TL)
@ 10 mA
(ns)
Thermal Impedance (θ)
Junction
Capacitance
(CJ) @ 0 V
(pF)
Junction
Capacitance
(CJ) @ 6 V
(pF)
Series
Resistance (RS)
@ 10 mA
(Ω)
Breakdown
Voltage (V)
I Region
(μm)
Average
1 μs Pulse
(qC/W)
(qC/W)
Part Number
Min – Max
15 – 30
Nominal
1
Typical
0.12
0.20
0.20
0.12
0.20
0.20
0.20
0.80
0.26
Maximum
0.10
Maximum
2.5
Typical
Maximum
120
80
Typical
15
CLA4601-000
CLA4602-000
CLA4603-000
CLA4604-000
CLA4605-000
CLA4606-000
CLA4607-000
CLA4608-000
CLA4609-000
5
5
15 – 30
1
0.15
2.0
10
20 – 45
1.5
2.0
2.0
2.5
7.0
7.0
28
0.15
2.0
5
100
100
70
10
30 – 60
0.10
2.5
7
10
30 – 60
0.15
2.0
7
7.0
7.0
1.2
0.3
0.3
45 – 75
0.15
2.0
10
50
100
1175
80
120 – 180
120 – 180
250 (Min.)
0.15 @ 50 V
0.50 @ 50 V
0.14
2.0
40
1.2
15
1.5
15
Note 1: Performance is guaranteed only under the conditions listed in this Table and is not guaranteed over the full operating or storage temperature ranges. Operation at elevated
temperatures may reduce reliability of the device.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
September 28, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200100I
2