Preliminary
Preliminary
SGA-1163 DC-6000 MHz 4ꢀ6V SiGe Amplifier
Specification
Test
Parameter
Min
Typ
Max
Unit
Condition
Bandwidth
Frequency Range
T= 25C
T= 25C
DC
6000
MHz
Device Bias
Operating Voltage
Operating Current
4ꢀ6
12
V
mA
500 MHz
Gain
T= 25C
T= 25C
T= 25C
T= 25C
11ꢀ8
3ꢀ1
8ꢀ7
-3ꢀ8
31ꢀ9
62ꢀ3
dB
dB
dBm
dBm
dB
Noise Figure
Output IP3
Output P1dB
Input Return Loss
Isolation
dB
850 MHz
Gain
11ꢀ5
3ꢀ1
7ꢀ9
-3ꢀ3
33ꢀ1
47ꢀ6
dB
dB
dBm
dBm
dB
Noise Figure
Output IP3
Output P1dB
Input Return Loss
Isolation
dB
1950 MHz
Gain
11ꢀ2
3ꢀ4
6ꢀ3
-4ꢀ6
15ꢀ7
34ꢀ3
dB
dB
dBm
dBm
dB
Noise Figure
Output IP3
Output P1dB
Input Return Loss
Isolation
dB
2400 MHz
Gain
11ꢀ4
3ꢀ4
5ꢀ7
-4ꢀ4
17ꢀ8
30ꢀ2
dB
dB
dBm
dBm
dB
Noise Figure
Output IP3
Output P1dB
Input Return Loss
Isolation
dB
Absolute Maximum Ratings
Parameter
Absolute Limit
Maxꢀ Device Current (ID)
Maxꢀ Device Voltage (VD)
Maxꢀ RF Input Power
24 mA
6 V
-9 dBm
Maxꢀ Junction Tempꢀ (TJ)
Operating Tempꢀ Range (TL)
+150°C
-40°C to +85°C
+150°C
Maxꢀ Storage Temp
ꢀ
Operation of this device beyond any one of these limits may
cause permanent damageꢀ For reliable continous operation,
the device voltage and current must not exceed the maximum
operating values specified in the table on page oneꢀ
Bias conditions should also satisfy the following expression:
IDVD < (TJ - TL) / RTH, j-l
522 Almanor Aveꢀ, Sunnyvale, CA 94085
Phone: (800) SMI-MMIC
2
http://wwwꢀsirenzaꢀcom
EDS-100934 Rev A