U637256
Recommended
Operating Conditions
Symbol
Conditions
Min.
Max.
Unit
Power Supply Voltage
Input Low Voltage
Input High Voltage
VCC
VIL
4.5
-0.3
2.2
5.5
0.8
V
V
V
-2 V at Pulse Width
10 ns permitted
VIH
VCC+0.3
C-Type
K-Type
DC Characteristics
Symbol
Conditions
Unit
Min. Max. Min. Max.
Operating Supply Currentb
ICC1
VCC
VIL
VIH
tc
= 5.5 V
= 0.8 V
= 2.2 V
= 70 ns
60
6
65
7
mA
Average Supply Current duringc
STORE
ICC2
VCC
E
W
VIL
VIH
= 5.5 V
≤ 0.2 V
≥ VCC-0.2 V
≤ 0.2 V
≥±VCC-0.2 V
mA
mA
Operating Supply Currentb
at tcR = 200 ns
(Cycling CMOS Input Levels)
ICC3
VCC
W
VIL
VIH
= 5.5 V
15
15
≥ VCC-0.2 V
≤ 0.2 V
≥ VCC-0.2 V
Standby Supply Currentd
(Cycling TTL Input Levels)
ICC(SB)1
VCC
E
tc
= 5.5 V
= VIH
= 70 ns
20
3
22
3
mA
mA
Standby Supply Curentd
(Stable CMOS Input Levels)
ICC(SB)
VCC
E
VIL
VIH
= 5.5 V
≥ VCC-0.2 V
≤ 0.2 V
≥ VCC-0.2 V
b: ICC1 and ICC3 are depedent on output loading and cycle rate. The specified values are obtained with outputs unloaded.
The current ICC1 is measured for WRITE/READ - ratio of 1/2.
c: ICC2 is the average current required for the duration of the SoftStore STORE cycle.
d: Bringing E±≥±VIH will not produce standby current levels until a software initiated nonvolatile cycle in progress has timed out.
See MODE SELECTION table. The current ICC(SB)1 is measured for WRITE/READ - ratio of 1/2.
August 15, 2006
STK Control #ML0054
3
Rev 1.1