 浏览型号STK14EC16-BF25I的Datasheet PDF文件第11页浏览型号STK14EC16-BF25I的Datasheet PDF文件第12页浏览型号STK14EC16-BF25I的Datasheet PDF文件第13页浏览型号STK14EC16-BF25I的Datasheet PDF文件第14页浏览型号STK14EC16-BF25I的Datasheet PDF文件第16页浏览型号STK14EC16-BF25I的Datasheet PDF文件第17页浏览型号STK14EC16-BF25I的Datasheet PDF文件第18页浏览型号STK14EC16-BF25I的Datasheet PDF文件第19页  
Preliminary  
STK14EC16  
PREVENTING AUTOSTORE  
The AutoStore function can be disabled by initiating  
an AutoStore Disable sequence. A sequence of  
READ operations is performed in a manner similar  
to the software STORE initiation. To initiate the  
AutoStore Disable sequence, the following  
sequence of E controlled or G controlled READ  
operations must be performed:  
1 Read Address 0x4E38 Valid READ  
2 Read Address 0xB1C7 Valid READ  
3 Read Address 0x83E0 Valid READ  
4 Read Address 0x7C1F Valid READ  
5 Read Address 0x703F Valid READ  
6 Read Address 0x8B45 AutoStore Disable  
The AutoStore can be re-enabled by initiating an  
AutoStore Enable sequence. A sequence of READ  
operations is performed in a manner similar to the  
software RECALL initiation. To initiate the  
AutoStore Enable sequence, the following  
sequence of E controlled or G controlled READ  
operations must be performed:  
Figure 4 - Current vs Cycle Time  
1 Read Address 0x4E38 Valid READ  
2 Read Address 0xB1C7 Valid READ  
3 Read Address 0x83E0 Valid READ  
4 Read Address 0x7C1F Valid READ  
5 Read Address 0x703F Valid READ  
6 Read Address 0x4B46 AutoStore Enable  
If the AutoStore function is disabled or re-enabled,  
a manual STORE operation (Hardware or Soft-  
ware) needs to be issued to save the AutoStore  
state through subsequent power down cycles. The  
part comes from the factory with AutoStore  
enabled, but best design practice is to set the  
enable or disable state during each power-up  
sequence and not depend on this factory default  
condition. Simtek recommends users configure the  
part completely for the specific application.  
15  
Simtek Confidential  
Rev 1.1  
Document Control #ML0061  
Jan, 2008  
 复制成功!