STK14CA8
Rev
1.2
Date
Change
September 2005
Added an Extended Temperature Range device tested from -55 degree
C to +85 degree C
1.3
December 2005
Parameter
Old Value
60 us
New Value
Notes
Typographical Error
In Datasheet
50 us
70 us
tRECALL
tSS
Undefined
100 Years at 20 Years @
Unspecified Max
New Data Retention
Temperature Temperature Specification
DATAR
1.4
1.5
March 2006
Removed Lead Plated Lead Finish
February 2007
Parameter
NVC
Old Value
New Value
Notes
New Nonvolatile
Store Cycle Spec
500K
200K
20 Years @ 20 Years @ New Data Retention
85 C
55 C
Spec
DATAR
2.55 V
No Min. Spec
VSWITCH Min.
-10 uA
Not Specified Before
Removed
IOUT (HSB)
tELAX, tGLAX
tEHAX, tGHAX
tDELAY Max.
tHLBL
20 ns
1 ns
New Spec
70 us
New Spec
300ns
Spec Not Required
70 uS Min.
70 uS Max. Typo
Supports Upgrades
From 14C88-3
tSS
57 uF
120 uF
V
CAP Max
Deleted -G Extended Temperature Option
Added tape and reel ordering option
Added product order code listing
Added package drawings
Reformated Entire Document
SIMTEK STK14CA8 Datasheet, February 2007
Copyright 2007, Simtek Corporation. All rights reserved.
This datasheet may only be printed for the expressed use of Simtek Customers. No part of the datasheet may be reproduced in any other
form or means without the express written permission from Simtek Corporation. The information contained in this publication is believed to be
accurate, but changes may be made without notice. Simtek does not assume responsibility for, or grant or imply any warranty, including
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE regarding this information, the product or its use. Nothing herein consti-
tutes a license, grant or transfer of any rights to any Simtek patent, copyright, trademark, or other proprietary right.
Rev 1.5
Document Control #ML0022
February 2007
19