SiI3114 PCI to Serial ATA Controller  
Data Sheet  
Silicon Image, Inc.  
Upon reception of an interlocked FIS (FISxxcfg[1:0] = '10'), the Link/Transport Logic sets the  
IntrlckFIS bit in the Smisc register. The following describes the possible sequence of events:  
ƒ Sequence 1:  
The Link Logic will continue to receive data while its buffer is being filled up.  
IntrlckFIS will cause an interrupt to the host.  
The first 7 Dwords of the FIS are available to the host in the RxFIS0 to RxFIS6  
registers.The driver will check the FIS type, clean up the PCI section, arm the  
DMA controller, and then assert the Rx_IFIS bit in the Smisc register.  
The Link/Transport Logic transfers the received FIS, including the header, through  
the PCI interface to the host.  
When all the data is received with no errors, the Link/Transport Logic will assert the  
IFIS_OK bit in the Smisc register. Otherwise one of the error bits will be set in  
the Serror register.  
The host will set the Accept_IFIS bit to accept or Reject_IFIS to reject the FIS.  
If no error is detected inside the frame and the Accept_IFIS bit is asserted, the  
Link/Transport Logic will send R_OK to the downstream device. If Reject_IFIS  
is asserted or any error is detected, the Link/Transport Logic will respond with  
R_ERR. Note that there is an interlock - if the frame is good, it will always wait  
for the Accept_IFIS or Reject_IFIS (if not asserted already) before responding.  
ƒ
Sequence 2:  
Link/Transport Logic will continue to receive data while its buffer is being filled up.  
IntrlckFIS will cause an interrupt to the host.  
Host reads the header; the driver will check the FIS type in RxFIS register and  
knows that the entire FIS is not larger than the size of RxFIS0 to 6 register.  
Host waits for IFIS_OK (if any error detected – the error signals).  
If IFIS_OK is received, host reads all data directly via PCI registers and then issues  
an Accept_IFIS (Link/Transport Logic to send R_OK) or a Reject_IFIS  
(Link/Transport Logic to send R_ERR).  
If any error is detected, host can ignore, the Link will respond with R_ERR anyway.  
SiI-DS-0103-D  
88  
© 2007 Silicon Image, Inc.  