欢迎访问ic37.com |
会员登录 免费注册
发布采购

SI3225-FQ 参数 Datasheet PDF下载

SI3225-FQ图片预览
型号: SI3225-FQ
PDF下载: 下载PDF文件 查看货源
内容描述: 双PROSLIC®可编程CMOS SLIC / CODEC [DUAL PROSLIC® PROGRAMMABLE CMOS SLIC/CODEC]
分类和应用: 电池电信集成电路
文件页数/大小: 108 页 / 1519 K
品牌: SILICONIMAGE [ Silicon image ]
 浏览型号SI3225-FQ的Datasheet PDF文件第27页浏览型号SI3225-FQ的Datasheet PDF文件第28页浏览型号SI3225-FQ的Datasheet PDF文件第29页浏览型号SI3225-FQ的Datasheet PDF文件第30页浏览型号SI3225-FQ的Datasheet PDF文件第32页浏览型号SI3225-FQ的Datasheet PDF文件第33页浏览型号SI3225-FQ的Datasheet PDF文件第34页浏览型号SI3225-FQ的Datasheet PDF文件第35页  
Si3220/Si3225  
Linefeed Operation States  
The linefeed interface includes eight different operating more details. The register and RAM locations used for  
states as shown in Table 17. The linefeed register programming the linefeed parameters are provided in  
settings (LF[2:0], linefeed register) are also listed. The Table 18. See “Loop Voltage and Current Monitoring”  
open state is the default condition in the absence of any and "Power Monitoring and Power Fault Detection" on  
pre-loaded register settings. The device may also page 35, and "Power Dissipation Considerations" on  
automatically enter the open state if excess power page 39 for detailed descriptions and register/RAM  
consumption is detected in the Si3200. See "Power locations for these functions.  
Monitoring and Power Fault Detection" on page 35 for  
Table 17. Linefeed States  
Open (LF[2:0] = 000).  
The Si3200 output is high-impedance. This mode can be used in the presence of line fault conditions and to  
generate open-switch intervals (OSIs). The device can also automatically enter the Open state if excess power  
consumption is detected in the Si3200 or in the discrete bipolar transistors.  
Forward Active (LF[2:0] = 001).  
Linefeed is active, but audio paths are powered down until an off-hook condition is detected. The Si3220 and  
Si3225 automatically enter a low-power state to reduce power consumption during on-hook standby periods.  
Forward On-Hook Transmission (LF[2:0] = 010).  
Provides data transmission during an on-hook loop condition (e.g., transmitting FSK caller ID information  
between ringing bursts).  
Tip Open (LF[2:0] = 011).  
Sets the portion of the linefeed interface connected to the TIP side of the subscriber loop to high-impedance  
and provides an active linefeed on the RING side of the loop for ground-start operation.  
Ringing (LF[2:0] = 100).  
Drives programmable ringing waveforms onto the subscriber loop (Si3220) or switches in a centralized ringing  
generator by driving an external relay (Si3225).  
Reverse Active (LF[2:0] = 101).  
Linefeed circuitry is active, but audio paths are powered down until an off-hook condition is detected. The  
Si3220 and Si3225 automatically enter a low-power state to reduce power consumption during on-hook  
standby periods.  
Reverse On-Hook Transmission (LF[2:0] = 110).  
Provide data transmission during an on-hook loop condition.  
Ring Open (LF[2:0] = 111).  
Sets the portion of the linefeed interface connected to the RING side of the subscriber loop to high impedance  
and provides an active linefeed on the TIP side of the loop for ground start operation.  
Rev. 1.0  
31  
 复制成功!