Si8430/31/35
1. Electrical Specifications
Table 1. Recommended Operating Conditions
Parameter
Symbol
Test Condition
Min
–40
Typ
25
—
Max
125*
5.5
Unit
°C
V
T
150 Mbps, 15 pF, 5 V
Ambient Operating Temperature*
A
V
V
2.70
2.70
DD1
DD2
Supply Voltage
—
5.5
V
*Note: The maximum ambient temperature is dependent on data frequency, output loading, number of operating channels,
and supply voltage.
Table 2. Absolute Maximum Ratings1
Parameter
Symbol
Min
–65
–40
–0.5
–0.5
–0.5
–0.5
—
Typ
—
—
—
—
—
—
—
—
—
Max
150
125
5.75
6.0
Unit
°C
°C
V
2
Storage Temperature
T
STG
Operating Temperature
Supply Voltage (Revision C)
Supply Voltage (Revision D)
Input Voltage
T
A
3
3
V
V
, V
, V
DD1
DD1
DD2
DD2
V
V
V
V
+ 0.5
V
I
DD
DD
Output Voltage
V
+ 0.5
V
O
Output Current Drive Channel
Lead Solder Temperature (10 s)
Maximum Isolation Voltage (1 s)
Notes:
I
10
mA
°C
O
—
260
—
3600
V
RMS
1. Permanent device damage may occur if the absolute maximum ratings are exceeded. Functional operation should be
restricted to conditions as specified in the operational sections of this data sheet.
2. VDE certifies storage temperature from –40 to 150 °C.
3. See "5. Ordering Guide" on page 27 for more information.
4
Rev. 1.5