Si8410/20/21
Table 6. Regulatory Information
CSA
The Si84xx is certified under CSA Component Acceptance Notice. For more details, see File 232873.
VDE
The Si84xx is certified according to IEC 60747-5-2. For more details, see File 5006301-4880-0001.
UL
The Si84xx is certified under UL1577 component recognition program to provide basic insulation to 2500 V
RMS
(1 minute). It is production tested > 3000 V
for 1 second. For more details, see File E257455.
RMS
Table 7. Insulation and Safety-related Specifications
Parameter
Symbol
L(IO1)
L(IO2)
Test Condition
Value
5.0 min
4.60
Unit
mm
mm
mm
Minimum Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
0.008
min
Tracking Resistance (Comparative Tracking
Index)
CTI
DIN IEC 60112/VDE 0303 Part 1
f = 1 MHz
>175
V
1
12
Resistance (Input-Output)
R
10
Ω
IO
1
Capacitance (Input-Output)
C
1.4
4.0
pF
pF
IO
2
Input Capacitance
C
I
Notes:
1. To determine resistance and capacitance, the Si84xx is converted into a 2-terminal device. Pins 1–4 are shorted
together to form the first terminal and pins 5–8 are shorted together to form the second terminal. The parameters are
then measured between these two terminals.
2. Measured from input pin to ground.
14
Preliminary Rev. 0.1