Si3056
Si3018/19/10
1. Electrical Specifications
Table 1. Recommended Operating Conditions
1
2
2
Parameter
Symbol
Test Condition
Min
Typ
25
Max
70
Unit
°C
Ambient Temperature
Si3056 Supply Voltage, Digital
Notes:
T
F and K-Grade
0
A
3
V
3.0
3.3
3.6
V
D
1. The Si3056 specifications are guaranteed when the typical application circuit (including component tolerance) and the
Si3056 and any Si3018 or Si3019 are used. See Figure 17 on page 18 for typical application schematic.
2. All minimum and maximum specifications are guaranteed and apply across the recommended operating conditions.
Typical values apply at nominal supply voltages and an operating temperature of 25 °C unless otherwise stated.
3. 3.3 V applies to both the digital and serial interface and the digital signals RGDT/FSD, OFHK, RESET, M0, and M.
Rev. 1.05