欢迎访问ic37.com |
会员登录 免费注册
发布采购

SI1002-C-GM 参数 Datasheet PDF下载

SI1002-C-GM图片预览
型号: SI1002-C-GM
PDF下载: 下载PDF文件 查看货源
内容描述: 超低功耗, 64/32 KB , 10位ADC, MCU ,集成了240-960兆赫的EZRadioPRO收发器 [Ultra Low Power, 64/32 kB, 10-Bit ADC MCU with Integrated 240-960 MHz EZRadioPRO Transceiver]
分类和应用:
文件页数/大小: 376 页 / 2369 K
品牌: SILICON [ SILICON ]
 浏览型号SI1002-C-GM的Datasheet PDF文件第308页浏览型号SI1002-C-GM的Datasheet PDF文件第309页浏览型号SI1002-C-GM的Datasheet PDF文件第310页浏览型号SI1002-C-GM的Datasheet PDF文件第311页浏览型号SI1002-C-GM的Datasheet PDF文件第313页浏览型号SI1002-C-GM的Datasheet PDF文件第314页浏览型号SI1002-C-GM的Datasheet PDF文件第315页浏览型号SI1002-C-GM的Datasheet PDF文件第316页  
Si1000/1/2/3/4/5  
TX  
RX  
RS-232  
LEVEL  
XLTR  
RS-232  
C8051Fxxx  
OR  
TX  
RX  
TX  
RX  
MCU  
C8051Fxxx  
Figure 25.3. UART Interconnect Diagram  
25.2.1. 8-Bit UART  
8-Bit UART mode uses a total of 10 bits per data byte: one start bit, eight data bits (LSB first), and one stop  
bit. Data are transmitted LSB first from the TX0 pin and received at the RX0 pin. On receive, the eight data  
bits are stored in SBUF0 and the stop bit goes into RB80 (SCON0.2).  
Data transmission begins when software writes a data byte to the SBUF0 register. The TI0 Transmit Inter-  
rupt Flag (SCON0.1) is set at the end of the transmission (the beginning of the stop-bit time). Data recep-  
tion can begin any time after the REN0 Receive Enable bit (SCON0.4) is set to logic 1. After the stop bit is  
received, the data byte will be loaded into the SBUF0 receive register if the following conditions are met:  
RI0 must be logic 0, and if MCE0 is logic 1, the stop bit must be logic 1. In the event of a receive data over-  
run, the first received 8 bits are latched into the SBUF0 receive register and the following overrun data bits  
are lost.  
If these conditions are met, the eight bits of data is stored in SBUF0, the stop bit is stored in RB80 and the  
RI0 flag is set. If these conditions are not met, SBUF0 and RB80 will not be loaded and the RI0 flag will not  
be set. An interrupt will occur if enabled when either TI0 or RI0 is set.  
MARK  
START  
BIT  
STOP  
BIT  
D0  
D1  
D2  
D3  
D4  
D5  
D6  
D7  
SPACE  
BIT TIMES  
BIT SAMPLING  
Figure 25.4. 8-Bit UART Timing Diagram  
25.2.2. 9-Bit UART  
9-bit UART mode uses a total of eleven bits per data byte: a start bit, 8 data bits (LSB first), a programma-  
ble ninth data bit, and a stop bit. The state of the ninth transmit data bit is determined by the value in TB80  
(SCON0.3), which is assigned by user software. It can be assigned the value of the parity flag (bit P in reg-  
ister PSW) for error detection, or used in multiprocessor communications. On receive, the ninth data bit  
goes into RB80 (SCON0.2) and the stop bit is ignored.  
Data transmission begins when an instruction writes a data byte to the SBUF0 register. The TI0 Transmit  
Interrupt Flag (SCON0.1) is set at the end of the transmission (the beginning of the stop-bit time). Data  
reception can begin any time after the REN0 Receive Enable bit (SCON0.4) is set to 1. After the stop bit is  
received, the data byte will be loaded into the SBUF0 receive register if the following conditions are met:  
312  
Rev. 1.0