Table 3.1. Global Electrical Characteristics (Continued)  
–40 to +85 °C, 25 MHz system clock unless otherwise specified.  
Parameter  
Conditions  
Min Typ Max  
Units  
Digital Supply Current—CPU Inactive (Idle Mode, not fetching instructions from Flash)  
2
V
V
V
V
V
V
= 3.6 V, F = 100 MHz  
= 3.6 V, F = 25 MHz  
= 3.0 V, F = 100 MHz  
= 3.0 V, F = 25 MHz  
= 3.0 V, F = 1 MHz  
= 3.0 V, F = 80 kHz  
36  
9
40  
12  
35  
9
mA  
mA  
mA  
mA  
mA  
µA  
DD  
DD  
DD  
DD  
DD  
DD  
I
DD  
30  
7
0.24  
19  
3
F = 25 MHz  
F = 1 MHz  
44  
%/V  
%/V  
I
I
Supply Sensitivity  
DD  
43.7  
0.24  
3,5  
V
V
V
V
= 3.0 V, F <= 1 MHz, T = 25 °C  
= 3.0 V, F > 1 MHz, T = 25 °C  
= 3.6 V, F <= 1 MHz, T = 25 °C  
= 3.6 V, F > 1 MHz, T = 25 °C  
mA/MHz  
DD  
DD  
DD  
DD  
Frequency Sensitivity  
DD  
0.25  
0.31  
0.32  
< 0.1  
mA/MHz  
mA/MHz  
mA/MHz  
µA  
Digital Supply Current  
(Stop Mode, shutdown)  
Oscillator not running,  
Monitor Disabled  
V
DD  
Notes:  
1. SYSCLK must be at least 32 kHz to enable debugging.  
2. SYSCLK is the internal device clock. For operational speeds in excess of 30 MHz, SYSCLK must be derived  
from the Phase-Locked Loop (PLL).  
3. Based on device characterization data; Not production tested.  
4. IDD can be estimated for frequencies < 20 MHz by simply multiplying the frequency of interest by the frequency  
sensitivity number for that range. When using these numbers to estimate IDD for >20 MHz, the estimate should  
be the current at 25 MHz minus the difference in current indicated by the frequency sensitivity number. For  
example: VDD = 3.0 V; F = 20 MHz, IDD = 15.9 mA - (25 MHz - 20 MHz) * 0.38 mA/MHz = 14 mA.  
5. Idle IDD can be estimated for frequencies < 1 MHz by simply multiplying the frequency of interest by the  
frequency sensitivity number for that range. When using these numbers to estimate Idle IDD for >1 MHz, the  
estimate should be the current at 25 MHz minus the difference in current indicated by the frequency sensitivity  
number. For example: VDD = 3.0 V; F = 5 MHz, Idle IDD = 7.2 mA - (25 MHz - 5 MHz) * 0.25 mA/MHz = 2.2 mA.  
Other electrical characteristics tables are found in the data sheet section corresponding to the associated  
peripherals. For more information on electrical characteristics for a specific peripheral, refer to the page  
indicated in Table 3.2.  
34  
Rev. 1.0  
 复制成功!