BATTERY PROTECTION IC FOR 1-CELL PACK
S-8241 Series
Rev.7.6_00
Table 3
Delay time
combination
Overcharge detection
Overdischarge detection
Overcurrent 1 detection
delay time
delay time
tCU
delay time
tDL
tlOV1
(1)
(2)
(3)
(4)
(5)
1.0 s
0.125 s
0.25 s
2.0 s
125 ms
31 ms
8 ms
16 ms
8 ms
125 ms
125 ms
31 ms
8 ms
0.25 s
16 ms
Remark The delay times can be changed within the range listed Table 4. For details, please contact our sales office.
Table 4
Delay time
Symbol
tCU
Selection range
0.5 s 1.0 s
62.5 ms 125 ms
8 ms 16 ms
Remarks
Overcharge detection delay time
0.25 s
31 ms
4 ms
2.0 s
⎯
Select a value from the left.
Select a value from the left.
Select a value from the left.
Overdischarge detection delay time tDL
Overcurrent 1 detection delay time tlOV1
⎯
Remark The value surrounded by bold lines is the delay time of the standard products.