欢迎访问ic37.com |
会员登录 免费注册
发布采购

S-8241ABPMC-GBPT2G 参数 Datasheet PDF下载

S-8241ABPMC-GBPT2G图片预览
型号: S-8241ABPMC-GBPT2G
PDF下载: 下载PDF文件 查看货源
内容描述: 电池保护IC 1格包 [BATTERY PROTECTION IC FOR 1-CELL PACK]
分类和应用: 电池光电二极管
文件页数/大小: 38 页 / 655 K
品牌: SII [ SEIKO INSTRUMENTS INC ]
 浏览型号S-8241ABPMC-GBPT2G的Datasheet PDF文件第18页浏览型号S-8241ABPMC-GBPT2G的Datasheet PDF文件第19页浏览型号S-8241ABPMC-GBPT2G的Datasheet PDF文件第20页浏览型号S-8241ABPMC-GBPT2G的Datasheet PDF文件第21页浏览型号S-8241ABPMC-GBPT2G的Datasheet PDF文件第23页浏览型号S-8241ABPMC-GBPT2G的Datasheet PDF文件第24页浏览型号S-8241ABPMC-GBPT2G的Datasheet PDF文件第25页浏览型号S-8241ABPMC-GBPT2G的Datasheet PDF文件第26页  
BATTERY PROTECTION IC FOR 1-CELL PACK  
S-8241 Series  
Rev.7.6_00  
2. <For products with power-down function>  
After having detected an overcurrent (overcurrent 1, overcurrent 2, short-circuiting), the state is  
held for the overdischarge detection delay time or longer without releasing the load, the condition  
changes to the power-down condition when the battery voltage drops below the overdischarge  
detection voltage. If the battery voltage drops below the overdischarge detection voltage due to  
overcurrent, the discharging control FET is turned off when the overcurrent is detected. If the  
battery voltage recovers slowly and if the battery voltage after the overdischarge detection delay  
time is equal to or lower than the overdischarge detection voltage, the S-8241 changes to the  
power-down condition.  
<For products without power-down function>  
After having detected an overcurrent (overcurrent 1, overcurrent 2, short-circuiting), the state is  
held for the overdischarge detection delay time or longer without releasing the load, the condition  
changes to the overdischarge condition when the battery voltage drops below the overdischarge  
detection voltage. If the battery voltage drops below the overdischarge detection voltage due to  
overcurrent, the discharging control FET is turned off when the overcurrent is detected. If the  
battery voltage recovers slowly and if the battery voltage after the overdischarge detection delay  
time is equal to or lower than the overdischarge detection voltage, the S-8241 changes to the  
overdischarge condition.  
8. 0 V Battery Charging Function  
This function enables the charging of a connected battery whose voltage is 0 V by self-discharge. When a charger  
having 0 V battery start charging charger voltage (V0CHA) or higher is connected between EB+ and EB- pins, the  
charging control FET gate is fixed to VDD potential. When the voltage between the gate and the source of the charging  
control FET becomes equal to or higher than the turn-on voltage by the charger voltage, the charging control FET is  
turned on to start charging. At this time, the discharging control FET is off and the charging current flows through the  
internal parasitic diode in the discharging control FET. If the battery voltage becomes equal to or higher than the  
overdischarge release voltage (VDU), the normal condition returns.  
Caution 1. Some battery providers do not recommend charging of completely discharged batteries. Please  
refer to battery providers before the selection of 0 V battery charging function.  
2. The 0 V battery charging function has higher priority than the abnormal charge current detection  
function. Consequently, a product with the 0 V battery charging function charges a battery and  
abnormal charge current cannot be detected during the battery voltage is low (at most 1.8 V or  
lower).  
3. When a battery is connected to the IC for the first time, the IC may not enter the normal condition  
in which discharging is possible. In this case, set the VM pin voltage equal to the VSS voltage  
(short the VM and VSS pins or connect a charger) to enter the normal condition.  
9. 0 V Battery Charge Inhibiting Function  
This function forbids the charging of a connected battery which is short-circuited internally (0 V battery). When the  
battery voltage becomes 0.9 V (typ.) or lower, the charging control FET gate is fixed to EB- potential to forbid charging.  
Charging can be performed, when the battery voltage is the 0 V battery charge inhibiting voltage (V0INH) or higher.  
Caution 1. Some battery providers do not recommend charging of completely discharged batteries. Please  
refer to battery providers before the selection of 0 V battery charging function.  
2. When a battery is connected to the IC for the first time, the IC may not enter the normal condition  
in which discharging is possible. In this case, set the VM pin voltage equal to the VSS voltage  
(short the VM and VSS pins or connect a charger) to enter the normal condition.  
22  
Seiko Instruments Inc.  
 复制成功!