3-WIRE REAL-TIME CLOCK
S-35190A
Rev.2.4_00
Configuration of Data Communication
1. Configuration of data communication
After setting the CS pin “H”, transmit the 4-bit fixed code “0110”, after that, transmit a 3-bit command and 1-bit Read/Write
command. Next, data is output or input from B7. Regarding details, refer to “ Serial Interface”.
Read/Write bit
Fixed code
Command
C1
0
1
1
0
C2
C0
R / W
1-byte data
B4 B3
B7
B6
B5
B2
B1
B0
Figure 13 Data Communication
Seiko Instruments Inc.
9