 浏览型号S-35190A-T8T1G的Datasheet PDF文件第9页浏览型号S-35190A-T8T1G的Datasheet PDF文件第10页浏览型号S-35190A-T8T1G的Datasheet PDF文件第11页浏览型号S-35190A-T8T1G的Datasheet PDF文件第12页浏览型号S-35190A-T8T1G的Datasheet PDF文件第14页浏览型号S-35190A-T8T1G的Datasheet PDF文件第15页浏览型号S-35190A-T8T1G的Datasheet PDF文件第16页浏览型号S-35190A-T8T1G的Datasheet PDF文件第17页  
3-WIRE REAL-TIME CLOCK  
S-35190A  
Rev.2.4_00  
2. Status register 1  
Status register 1 is a 1-byte register that is used to display and set various modes. The bit configuration is shown below.  
B6  
B5  
B4  
B3  
B2  
B1  
B0  
B7  
INT1  
R
INT2  
R
BLD  
R
POC  
R
RESET  
W
SC0  
R/W  
SC1  
R/W  
12 / 24  
R/W  
R:  
Read  
Write  
Read/Write  
W:  
R/W:  
Figure 15 Status Register 1  
B0 : POC  
This flag is used to confirm whether the power is on. The power-on detector operates at power-on and B0 is set to “1”.  
This flag is Read-only. Once it is read, it is automatically set to “0”. When this flag is “1”, be sure to initialize. Regarding  
the operation after power-on, refer to „ Power-on Detection Circuit and Register Status”.  
B1 : BLD  
This flag is set to “1” when the power supply voltage decreases to the level of detection voltage (VDET) or less. Users  
can detect a drop in the power supply voltage. This flag is set to “1” once, is not set to “0” again even if the power  
supply increases to the level of detection voltage (VDET) or more. This flag is Read-only. When this flag is “1”, be sure  
to initialize. Regarding the operation of the power supply voltage detection circuit, refer to „ Low Power Supply  
Detection Circuit”.  
B2 : INT2, B3 : INT1  
This flag indicates the time set by alarm and when the time has reached it. This flag is set to “1” when the time that  
users set by using the alarm interrupt function has come. The INT1 flag in “1” at alarm 1 interrupt mode, the INT2 flag  
in “1” at alarm 2 interrupt mode. This flag is Read-only. This flag is read once, is set to “0” automatically.  
B4 : SC1, B5 : SC0  
These flags are SRAM type registers, they are 2 bits as a whole, can be freely set by users.  
B6 : 12 / 24  
This flag is used to set 12-hour or 24-hour expression.  
0 : 12-hour expression  
1 : 24-hour expression  
B7 : RESET  
The internal IC is initialized by setting this bit to “1”. This bit is Write-only. It is always “0” when Read. When applying  
the power supply voltage to the IC, be sure to write “1” to this bit to initialize the circuit. Regarding each status of data  
after initialization, refer to „ Register Status After Initialization”.  
Seiko Instruments Inc.  
13  