 浏览型号S-35190A-T8T1G的Datasheet PDF文件第30页浏览型号S-35190A-T8T1G的Datasheet PDF文件第31页浏览型号S-35190A-T8T1G的Datasheet PDF文件第32页浏览型号S-35190A-T8T1G的Datasheet PDF文件第33页浏览型号S-35190A-T8T1G的Datasheet PDF文件第35页浏览型号S-35190A-T8T1G的Datasheet PDF文件第36页浏览型号S-35190A-T8T1G的Datasheet PDF文件第37页浏览型号S-35190A-T8T1G的Datasheet PDF文件第38页  
3-WIRE REAL-TIME CLOCK  
S-35190A  
Rev.2.4_00  
„ Flowchart of Initialization at Power-on and Example of Real-time Data Set-up  
Figure 41 shows the flowchart of initialization at power-on and an example of real-time data set-up. Regarding how to apply  
power, refer to „ Power-on Detection Circuit and Register Status”. It is unnecessary for users to comply with this  
flowchart of real-time data strictly. And if using the default data at initializing, it is also unnecessary to set up again.  
START  
Power-on  
Wait for 0.5 s  
Read status register 1  
NO  
POC = 1  
YES  
Initialization after power-on  
Initialize  
(status register 1 B7 = 1)  
Read status register 1  
NO  
POC = 0  
YES  
NO  
BLD = 0  
YES  
Set 24-hour/12-hour  
display to status register 1  
Read status register 1  
NG  
Confirm data in status  
register 1  
Example of real-time data setting  
OK  
Set real-time data 1  
Read real-time data 1  
Read status register 2  
NO  
TEST = 0  
YES  
END  
Figure 41 Example of Initialization Flowchart  
34  
Seiko Instruments Inc.  