3RT, 3RH, 3TB, 3TC, 3TH, 3TK Contactors for Special Applications
3TK1 Contactors for Switching Resistive Loads (AC-1)
4-pole, 4 NO, 200 ... 1000 A
■
Overview
EN 60947-4-1 (VDE 0660 Part 102)
The contactors also comply with the requirements of
NFC 63–110 and NFC 20–040.
The contactors are suitable for use in any climate. They are
finger-safe according to EN 50274. Terminal covers may have to
be fitted onto the connecting bars, depending on the
configuration with other devices.
Solenoids for 3TK10 to 3TK13 contactors: as withdrawable coils.
Surge suppression
Control circuit
Solenoids for 3TK1 contactors: can be retrofitted with
RC elements.
Screw terminals
Screw mounting
3TK13
Rated data AC-1
Auxiliary
contacts
Version
Rated control
supply voltage
U
s
DT Order No.
Price
per PU
PU
(UNIT,
SET, M)
PS*
PG
Weight
per PU
approx.
Operational
current
I
e
up to 690 V
(at 40 °C)
A
200
Ratings of AC loads
(p.f. = 0.95) at
230 V 400 V 690 V 1000 V
kW
75
kW
130
kW
225
kW
205
NO
2
NC
2
V AC
220 ... 230, 50 Hz
230 ... 240, 50 Hz
110/120, 50/60 Hz
24, 50 Hz
220 ... 230, 50 Hz
230 ... 240, 50 Hz
110/120, 50/60 Hz
24, 50 Hz
220 ... 230, 50 Hz
230 ... 240, 50 Hz
110/120, 50/60 Hz
24, 50 Hz
220 ... 230, 50 Hz
230 ... 240, 50 Hz
110/120, 50/60 Hz
24, 50 Hz
B
D
C
D
B
D
D
D
B
D
D
D
B
D
D
D
3TK10 42-0AP0
3TK10 42-0AU0
3TK10 42-0AF0
3TK10 42-0AB0
3TK11 42-0AP0
3TK11 42-0AU0
3TK11 42-0AF0
3TK11 42-0AB0
3TK12 42-0AP0
3TK12 42-0AU0
3TK12 42-0AF0
3TK12 42-0AB0
3TK13 42-0AP0
3TK13 42-0AU0
3TK13 42-0AF0
3TK13 42-0AB0
3TK14 42-0AP0
3TK14 42-0AU0
3TK14 42-0AF0
3TK15 42-0AP0
3TK15 42-0AU0
3TK15 42-0AF0
3TK17 42-0AP0
3TK17 42-0AU0
3TK17 42-0AF0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
101
kg
4.423
4.449
4.379
4.432
4.746
4.476
4.634
4.738
7.158
7.167
7.127
7.129
7.156
7.172
7.118
7.136
18.938
19.041
19.094
19.068
19.100
19.076
20.030
20.080
20.100
AC operation
250
90
165
280
200
2
2
300
110
195
340
325
2
2
350
130
230
395
370
2
2
550
205
360
620
510
2
2
220 ... 230, 50 Hz
1)
B
230 ... 240, 50 Hz
D
110/120, 50/60 Hz C
220 ... 230, 50 Hz
1)
B
230 ... 240, 50 Hz
D
110/120, 50/60 Hz C
220 ... 230, 50 Hz
1)
B
230 ... 240, 50 Hz
D
110/120, 50/60 Hz D
800
300
525
905
575
2
2
1000
375
655
1135
--
2
2
For accessories, see page 3/134 onwards.
For spare parts, see page 3/142 onwards.
1) At 60 Hz: 240 V.
* You can order this quantity or a multiple thereof.
Siemens LV 1 · 2006
3/61
3
■
Selection and ordering data