3RT, 3RH, 3TB, 3TC, 3TH, 3TK Contactors for Special Applications
3RT13 Contactors for Switching Resistive Loads (AC-1)
4-pole, 4 NO, 18 ... 140 A
■
Overview
AC and DC operation
EN 60947-4-1 (VDE 0660, Part 102)
The contactors are suitable for use in any climate. They are
finger-safe according to EN 50274.
The accessories for the 3-pole SIRIUS contactors can also be
used for the 4-pole versions.
■
Selection and ordering data
3
AC operation, 4 NO contacts
Screw terminals
Rated data AC-1,
T
u
: 40/60 °C
Operational Ratings of
current
I
e
AC loads
(p.f. = 0.95) at
50 Hz and
400 V
A
kW
Rated control
supply voltage
U
s
DT
Screw terminals
PU
PS*
(UNIT,
SET, M)
Price
per PU
PG
Weight
per PU
approx.
Order No.
V
kg
For screw and snap-on mounting onto 35 mm standard mounting rails
Size S00
1)
18 / 16
12 / 11
24, 50/60 Hz
110, 50/60 Hz
230, 50/60 Hz
24, 50/60 Hz
110, 50/60 Hz
230, 50/60 Hz
24, 50 Hz
110, 50 Hz
230, 50 Hz
24, 50 Hz
110, 50 Hz
230, 50 Hz
}
}
}
}
}
}
}
}
}
}
}
}
3RT13 16-1AB00
3RT13 16-1AF00
3RT13 16-1AP00
3RT13 17-1AB00
3RT13 17-1AF00
3RT13 17-1AP00
3RT13 25-1AB00
3RT13 25-1AF00
3RT13 25-1AP00
3RT13 26-1AB00
3RT13 26-1AF00
3RT13 26-1AP00
1
1
1
1
1
1
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
101
101
101
101
101
101
101
101
101
101
101
101
0.206
0.204
0.203
0.205
0.203
0.203
0.393
0.392
0.394
0.393
0.391
0.394
22 / 20
14.5 / 13
Size S0
3RT13 1.-1A.00
35 / 30
2)
22 / 20
40 / 35
2)
26 / 23
3RT13 2.-1A.00
Size S00:
Sizes S0 to S3:
Snap-on auxiliary switch blocks according to EN 50005.
Snap-on auxiliary switch blocks according to EN 50012 and EN 50005
(for S0 max. 2 auxiliary contacts, please note information in the Catalog LV 1 T).
For other voltages, see page 3/29.
For accessories, see page 3/110.
For spare parts, see page 3/126.
1) For size S00: coil operating range
at 50 Hz: 0.8 ... 1.1 x
U
s
,
at 60 Hz: 0.85 ... 1.1 x
U
s
.
2) Minimum conductor cross-section 10 mm².
AC operation, 4 NO contacts
Cage Clamp terminals
Rated data AC-1,
T
u
: 40/60 °C
Operational Ratings of
current
I
e
AC loads
(p.f. = 0.95) at
50 Hz and
400 V
A
kW
Rated control
supply voltage
U
s
DT
Cage Clamp terminals
PU
PS*
(UNIT,
SET, M)
PG
Weight
per PU
approx.
Order No.
Price
per PU
V
kg
For screw and snap-on mounting onto 35 mm standard mounting rails
Size S00
1)
18 / 16
12 / 11
24, 50/60 Hz
110, 50/60 Hz
230, 50/60 Hz
24, 50/60 Hz
110, 50/60 Hz
230, 50/60 Hz
B
B
}
B
B
}
3RT13 16-2AB00
3RT13 16-2AF00
3RT13 16-2AP00
3RT13 17-2AB00
3RT13 17-2AF00
3RT13 17-2AP00
1
1
1
1
1
1
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
101
101
101
101
101
101
0.202
0.198
0.202
0.201
0.200
0.201
22 / 20
14.5 / 13
Size S00:
Snap-on auxiliary switch blocks according to EN 50005.
For other voltages, see page 3/29.
For accessories, see page 3/110.
For spare parts, see page 3/127.
1) For size S00: coil operating range
at 50 Hz: 0.8 ... 1.1 x
U
s
,
at 60 Hz: 0.85 ... 1.1 x
U
s
.
* You can order this quantity or a multiple thereof.
3/58
Siemens LV 1 · 2006