欢迎访问ic37.com |
会员登录 免费注册
发布采购

1200000 参数 Datasheet PDF下载

1200000图片预览
型号: 1200000
PDF下载: 下载PDF文件 查看货源
内容描述: [MULTIPLE LIGHT BEAM SAFETY DEVICES]
分类和应用:
文件页数/大小: 8 页 / 1181 K
品牌: SICK [ SICK AG ]
 浏览型号1200000的Datasheet PDF文件第1页浏览型号1200000的Datasheet PDF文件第2页浏览型号1200000的Datasheet PDF文件第3页浏览型号1200000的Datasheet PDF文件第4页浏览型号1200000的Datasheet PDF文件第5页浏览型号1200000的Datasheet PDF文件第7页浏览型号1200000的Datasheet PDF文件第8页  
M40S-072200AR0, M40E-072200RR0 | M4000 Standard  
MULTIPLE LIGHT BEAM SAFETY DEVICES  
Number of beams  
Beam separation S1  
500 (19.69)  
600 (23.62)  
220 (8.66)  
L1  
L2  
A
B
C
D
E
F
2
643 (25.31)  
743 (29.25)  
583 (22.95)  
943 (37.13)  
1,043 (41.06)  
803 (31.61)  
1,043 (41.06)  
1,023 (40.28)  
1,243 (48.94)  
1,462 (57.56)  
1,682 (66.22)  
672 (26.46)  
772 (30.39)  
612 (24.09)  
972 (38.27)  
1,072 (42.20)  
832 (32.76)  
1,072 (42.20)  
1,052 (41.42)  
1,272 (50.08)  
1,491 (58.70)  
1,711 (67.36)  
3
4
400 (15.75)  
450 (17.72)  
220 (8.66)  
300 (11.81)  
220 (8.66)  
5
6
7
8
Connection diagram  
M4000 Standard connected to UE10-3OS safety relay  
+24 V  
M4000S  
Standard  
M4000R  
Standard  
H
I
S1  
BN  
2
5
1
3
4
6
7
2
BN  
WH  
GN  
YE  
+24 V  
Test  
+24 V  
RES  
1
3
ADO  
n.c.  
n.c.  
4
EDM  
5
GR  
PK  
BU  
SH  
n.c.  
n.c.  
GND  
FE  
OSSD1  
OSSD2  
GND  
6
BU  
SH  
7
FE  
FE  
B1 B3  
Y1 13 23 33 41  
1)  
J
H3  
UE10-3OS  
B2 B4  
Y2 14 24 34 42  
K
L
0 V  
E119914/00/2014-07-29  
2) PELV  
Task  
Connection of an M4000 Standard multiple light beam safety device to a UE10-3OS safety relay.  
Operating mode: with restart interlock and external device monitoring.  
Operating characteristics  
M
N
O
P
Q
R
S
T
When the light path is clear and the UE10-3OS is de-energized and functioning correctly, the yellow LED on the receiver and the H3  
lamp flash. The system is ready for switch-on and waits for an input signal/switch-on signal. The system is enabled by pressing and  
releasing the S1 button. The OSSD1 and OSSD2 outputs are live, the UE10-3OS is switched on. On interruption of one or several of  
the light beams, the UE10-3OS is de-energized by the OSSD1 and OSSD2 outputs.  
Fault analysis  
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The erroneous behavior of the  
UE10-3OS will be detected. The shutdown function is retained. On manipulation (e.g., jamming) of the S1 button, the system does  
not enable the output current circuits.  
Comments  
1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state  
is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z  
path) is only possible with a single-channel control and by taking the risk analysis into account.  
2) PELV in accordance with the requirements in EN 60204-1 / 6.4  
Take note of the operating instructions of the integrated devices.  
6
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK  
Online data sheet | 2017-08-24 18:11:25  
Subject to change without notice  
 复制成功!