DG996049
MODEL No.
GL6ZR27
Jun/16/99
PAGE
6110
5. Incoming inspection
5- 1. Applied standard : IS0 2859-l
5-2. Sampling method and level : A single sampling plannormal inspection level II
: AQL Major defect : 0.065%
Minor defect : 0.4%
5-3. Test items, judgement criteria and classifica of defect
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
Test items
Disconnection
Position of Cutting off
rim
Reverse terminal
Outline dimensions
characteristics
Cut off the rim
Foreign substance
Scratch
Void
Uneven density of
material
for scattering
Unbalanced center
Burr
Insertion position of
terminal
judgement criteria
Not emit light
Different from dimension
Different from dimension
Not satisfy outline specification
Over the limit value of specification at Vr, Ia, and Iv
Exceed -0.2mm
White point : Exceed 4 0.3mm (on top view)
Black point : Exceed 4 0.3mm (on top view)
String form : Exceed 3.Omm (on top view)
Exceed 4 0.3mm or O.lmm x LOnun (on top view)
Exceed 4 0.3mm (on top view)
Extremely uneven density
Exceed fo.25mm from package center
Exceed +0.2mm againstprovided dimension
Insertion position of terminal
Minor defect
Major defect
classifica of defec
5-4. Test items the surface is be applied for flat type, judgement criteria and classifica of defect
No.
14
15
Test items
Chapped the surface
Hollow the surface
judgement criteria
The surface chapped is striking for see the lamp top
The surface hollow is striking for see the lamp top
classifica of defect
Minor defect