This example is achieved by programming the Sequencer as follows:
Table 37 Beacon Mode Settings
Variable
Effect
IdleMode
1 : Sleep mode
FromStart
LowPowerSelection
FromIdle
00 : To LowPowerSelection
1 : To Idle state
0 : To Transmit state on T1 interrupt
FromTransmit
0 : To LowPowerSelection on PacketSent interrupt
T
T
define the time between the start of two transmissions.
Timer1 + Timer2
Rev 3 - August 2012