4.5.4. Sequencer State Machine  
The following graphs summarize every possible transition between each Sequencer state. The Sequencer states are  
highlighted in grey. The transitions are represented by arrows. The condition activating them is described over the  
transition arrow. For better readability, the start transitions are separated from the rest of the graph.  
Transitory states are highlighted in light grey, and exit states are represented in red. It is also possible to force the  
Sequencer off by setting the Stop bit in RegSeqConfig1 to 1 at any time.  
Sequencer: Start transitions  
Sequencer Off  
&
Initial mode = Sleep or Standby  
On SequencerStart bit rising edge  
Start  
On FifoThreshold  
if FromStart = 11  
If FromStart = 00  
If FromStart = 01  
If FromStart = 10  
LowPower  
Selection  
Receive  
Transmit  
Sequencer: State machine  
Standby if IdleMode = 0  
Sleep if IdleMode = 1  
If LowPowerSelection = 1  
If LowPowerSelection = 0  
( Mode Þ eInitial mode )  
LowPower  
Selection  
Sequencer Off  
Idle  
On T1 if FromIdle = 0  
If FromPacketReceived = 000  
If FromPacketReceived = 010  
On T1 if FromIdle = 1  
Packet  
Received  
On PayloadReady  
if FromReceive = 010  
If FromPacketReceived = 100  
Via FS mode if FromPacketReceived = 011  
On PayloadReady if FromReceive = 001  
On CrcOk if FromReceive = 011  
On T2  
On PayloadReady if FromReceive = 011 Receive  
(CRC failed and CrcAutoClearOn=0)  
On Rssi if FromReceive = 100  
On SyncAdress if FromReceive = 101  
On Preamble if FromReceive = 110  
On RxTimeout  
On PacketSent  
if FromTransmit = 1  
On PacketSent  
if FromTransmit = 0  
Via ReceiveRestart  
if FromRxTimeout = 00  
Transmit  
If FromRxTimeout = 10  
If FromRxTimeout = 11  
If FromRxTimeout = 01  
Sequencer Off  
RxTimeout  
Figure 22. Sequencer State Machine  
Use cases of the Top Sequencer are detailed in Section 7.  