SS2609
Hall Latch - High Sensitivity
Absolute Maximum Ratings
Parameter
Supply Voltage
Symbol
Value
28
Units
V
VDD
IDD
VOUT
IOUT
TA
Supply Current
50
mA
V
Output Voltage
28
Output Current
50
mA
°C
Operating Temperature Range
Storage Temperature Rang
ESD Sensitivity
-40 to 85
-50 to 150
4000
TS
°C
-
V
Operating Temperature Range Symbol
Value
Units
°C
Temperature Suffix “ E”
Temperature Suffix “ K”
Temperature Suffix “ L”
TA
TA
TA
-40 to 85
-40 to 125
-40 to 150
°C
°C
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum- rated conditions for ex-
tended periods may affect device reliability.
General Electrical Specifications
DC Operating Parameters TA = 25°C, VDD= 2.5V to 5.5V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Operating
Min
Typ
Max
Units
VDD
Operating voltage
2.5
3
5.5
V
IDD
Supply current
Average
45
μA
Output Current
IOUT
VSAT
TAW
TSL
1.0
mA
V
Saturation Voltage
Awake mode time
Sleep mode time
IOUT=1mA
Operating
Operating
0.4
20
μS
μS
600
Magnetic Specifications
DC Operating Parameters VDD = 2.5 to 5.5V (unless otherwise specified)
Package
Parameter
Symbol
BOP
Test Conditions
Min
Typ
Max
40
Units
Operating Point
Release Point
Hysteresis
5
25
-25
40
G
G
G
G
G
G
Ta=25°C
UA
BRP
-40
-5
Vdd=2.75V DC
BHYST
BOP
Operating Point
Release Point
Hysteresis
-40
5
-25
25
-5
Ta=25°C
SO
BRP
40
Vdd=2.75V DC
BHYST
40
3
V3.10 Nov 1, 2013