SA9603C  
6. Register Values  
a.  
The active and reactive energy measured per count, may be calculated by  
applying the following formula:  
V
I
*
K
Energy per Count  
=
Watt seconds  
Where  
V
I
K
=
=
=
Rated Voltage  
Rated Current  
9281  
for Active Energy  
9281  
2
*
for Reactive Energy  
π
b.  
c.  
The mains frequency may be calculated as follows:  
Crystal frequency  
Register Value 8  
*
Frequency =  
To calculate the measured voltage, the following formula may be used:  
V n  
*
Vmeasured =  
14000  
t
*
Where  
V
t
n
=
=
=
rated mains voltage  
time difference between successive reads  
difference in register values between  
successive reads  
7. Software Flow  
The SA9603C is able to execute code written for the SA9103C without any  
modifications. (Ensure that only bits of the serial command to the device is set that  
need to be set.)  
It is suggested that the DUMP command is used in cases where more than one  
register is continuously read. The DUMP command initiates a serial transmission  
of successive register values, starting with the specified register. The Dump  
command does not reset the register values.  
New software should be developed in such a way that registers are never resettled  
and must allow for register overflow. Register overflow is easily taken into account  
by software running on a controlling microcontroller. The software subtracts the  
previous register value from the current register value in order to determine the  
actual change in register value. Note that the mains frequency register value only  
needs to be scaled, in order to calculate the true mains frequency in Hertz.  
The SA9603C integrated circuit only transmits the register values after completion  
of the current measurement cycle (8 mains periods maximum).  
The delay of 8 mains periods may be calculated from the period value of the  
frequencyreturnedbytheinitialread, andupdatedwitheachsubsequentfrequency  
reading.  
10/18  