SA4104A / SA4104B  
Reverse Energy Flow Indication  
The SA4104A/B assesses the phase difference between the  
voltage channel signal and the current channel signal. If this  
phase difference is greater than 90 degrees then the DIRO  
signal will become active. This facility is designed to detect  
the wrongful connection of the meter. This operation is fully  
described in the Output Signals section.  
meter. This reading is independent of time and will be  
repeatable so as to consistently achieve the required  
accuracy for the full input current range that needs to be  
measured to IEC62053 accuracy. In Figure 6 the reference  
meter pulses are counted between two pulses of the meter  
under test. The meter under test is then adjusted so as to  
reflect the expected number of counted reference meter  
pulses. A worst-case scenario is for measurements obtained  
for only two pulses of the meter under test and N pulses from  
the reference meter. In this case the measurement resolution  
will be:  
Starting Current  
The SA4104A/B generates pulses on the LED and  
MON/MOP outputs for an input power greater than 0.01% or  
0.004% of FMAX depending on whether version A or version B  
of the device is used. This is to comply with the IEC  
requirement where the meter is required to generate pulses  
for currents greater than 0.4%Ib.  
1
(
)
ꢇ푒푎푠푢푟푒푚푒푛푡 ꢈ푒푠표푙푢푡ꢀ표푛 % = × 100  
The corresponding calibration and repeatability results can  
never be more accurate than this measurement resolution.  
Calibration and Repeatability  
The SA4104A/B provides an output (LED) that is used for  
calibration of the meter. The meter is calibrated by comparing  
the energy reading of the meter under test with the energy  
reading of the reference meter. The reference meter should  
have a considerably higher pulse rate than the meter under  
test. The accuracy to which the meter has to be calibrated will  
dictate how much higher the reference meter pulse rate has  
to be. The SA4104A/B can be calibrated to specification with  
a minimum of two pulses on the LED output whilst in  
STANDARD mode and utilizing an appropriate reference  
Power-On Reset  
The SA4104A/B has a power-on reset circuitry that activates  
whenever the voltage between VDD and VSS is less than  
3.6V ± 8%.  
Power Consumption  
The power consumption of the SA4104A/B integrated circuit  
is less than 30mW.  
N pulses  
……….  
……….  
Voltage  
Neutral  
Single  
Phase  
Test  
VIN  
N
VIN  
N
Meter Under  
Test  
SA4104A/B  
Reference  
Meter  
Source  
Pulse Out  
IOUT  
LED  
IIN  
IIN  
IOUT  
Current  
Figure 6: Calibration and repeatability setup  
SPEC-1654 (REV. 4)  
29-09-2017  
8/18