欢迎访问ic37.com |
会员登录 免费注册
发布采购

SA4104ASAR 参数 Datasheet PDF下载

SA4104ASAR图片预览
型号: SA4104ASAR
PDF下载: 下载PDF文件 查看货源
内容描述: [Single Channel Single Phase Energy]
分类和应用:
文件页数/大小: 18 页 / 564 K
品牌: SAMES [ SAMES ]
 浏览型号SA4104ASAR的Datasheet PDF文件第1页浏览型号SA4104ASAR的Datasheet PDF文件第2页浏览型号SA4104ASAR的Datasheet PDF文件第3页浏览型号SA4104ASAR的Datasheet PDF文件第5页浏览型号SA4104ASAR的Datasheet PDF文件第6页浏览型号SA4104ASAR的Datasheet PDF文件第7页浏览型号SA4104ASAR的Datasheet PDF文件第8页浏览型号SA4104ASAR的Datasheet PDF文件第9页  
SA4104A / SA4104B  
PIN DESCRIPTION  
Designation  
Pin No.  
Description  
Analog Ground. This is the reference pin for the current and voltage signal sensing  
AGND  
16  
networks. The supply voltage to this pin should be mid-way between VDD and VSS  
.
Positive Supply Voltage. The voltage to this pin should be +2.5V ± 10% with respect to  
AGND.  
VDD  
VSS  
8
12  
Negative Supply Voltage. The voltage to this pin should be -2.5V ± 10% with respect to  
AGND.  
Analog Input for Voltage. The maximum current into the voltage sense input IVP should be  
set at 16µARMS. The voltage sense input saturates at an input current of ±25µA peak.  
IVP  
15  
Analog Inputs for Current. The maximum current into the current sense inputs IIP/IIN should  
be set at 16µARMS. The current sense inputs saturate at an input current of ±25µA peak.  
IIP, IIN  
2, 1  
3
This pin provides the connection for the reference current setting resistor. A 47kresistor  
connected to VSS sets the optimum operating conditions.  
VREF  
Rated Condition Select inputs. These input pins are used for selecting between the different  
rated condition configurations. Refer to the Rated Condition Select section.  
R0, R1, R2, R3  
6, 5, 4, 9  
Fast Mode Select input. This three state input is used to select between STANDARD and  
FAST mode and provides an extended selection of meter constants. Refer to the Rated  
Condition Select and Fast Mode Select sections.  
FMS  
7
DIRO  
LED  
14  
11  
Direction Indicator output. This output indicates the direction of energy flow.  
Calibration LED output. Refer to the Rated Condition Select section for the pulse rate output  
options.  
Motor pulse outputs. These outputs can drive an electro-mechanical counter directly. Refer  
to the Rated Condition Select section for the pulse rate output options.  
MON, MOP  
13, 10  
1
2
3
4
5
6
7
8
16  
15  
14  
13  
12  
11  
10  
9
IIN  
IIP  
AGND  
IVP  
ORDERING INFORMATION  
Part Number  
SA4104ASAR  
SA4104BSAR  
Device  
Package  
SA4104A  
SA4104B  
SOIC16 (RoHS compliant)  
SOIC16 (RoHS compliant)  
VREF  
R2  
DIRO  
MON  
VSS  
LED  
MOP  
R3  
R1  
R0  
FMS  
VDD  
Figure 3: Pin connections  
SPEC-1654 (REV. 4)  
29-09-2017  
4/18