OUTPUT SIGNALS
INPUT SIGNALS
Pulse outputs (P1, P2)
Voltage reference (VREF)
The output on P1 and P2 is a pulse density signal representing
the instantaneous power/energy measurement as shown in
A bias resistor of 24kW sets optimum bias conditions on chip.
Calibration of the SA2007H should be done in the micro-
controllers software.
figure 4. The pulse width t on P1 and P2 change with the
p
direction of energy measurement t is 71.5µs for positive
p
energy and doubles (143µS) if negative energy is measured.
The output frequency may be calculated using the following
formula:
Output Mode (OMODE)
The output behavior of the SA2007H is selectable between
fixed width outputs or latched outputs. In fixed width mode the
P1 and P2 output pulses stay at a fixed width. In latched mode
the status of P1 and P2 are cleared with a logic 1 on the RP pin.
2
f = 11.16 x FOUT x ( I x I ) / I
R
I
V
Where:
FOUT= Typical rated output frequency (1360Hz)
Refer to the “Output signals in latched mode” section (Page 6)
for further information.
I
I
I
=
=
=
Input current on current sense input (16µA at rated
conditions)
Input current on voltage sense input (14µA at rated
conditions)
I
Description
OMODE
V
0
Fixed width mode
ReferencecurrentonVREFtypically50µA
R
Latched mode
1
An integrated anti-creep function does not allow output pulses
onP1orP2ifnopowerismeasuredbythedevice.
Clear Interrupt (RP)
A logic 1 on the RP input is used to clear the interrupt
generated by the SA2007H when a pulse is generated on P1
or P2, while operating in latched mode. By clearing the
interrupt in latched mode the status of the pulse outputs will
also be cleared.
v
MAINS
t
Test Inputs (TEST, TCLK)
For normal operations these pins must be connected to V .
SS
POWER
V x I
t
FOUT
t
DR-01282
t
P
Figure 4: FOUT instantaneous pulse output
Direction indication (D1, D2)
The SA2007H provides information about the energy flow
direction of both current channels separately on pins D1 and
D2.
Logic 0 on pin D1 or D2 indicates reverse energy flow of that
particular channel. Reverse energy flow is defined as the
condition where the voltage sense input and current sense
input are out of phase (greater than 90 degrees).
5/10
http://www.sames.co.za
PRELIMINARY