SA2007H  
ssaammeess  
OUTPUT SIGNALS  
INPUT SIGNALS  
Pulse outputs (P1, P2)  
Voltage reference (VREF)  
The output on P1 and P2 is a pulse density signal representing  
the instantaneous power/energy measurement as shown in  
A bias resistor of 24kW sets optimum bias conditions on chip.  
Calibration of the SA2007H should be done in the micro-  
controllers software.  
figure 4. The pulse width t on P1 and P2 change with the  
p
direction of energy measurement t is 71.5µs for positive  
p
energy and doubles (143µS) if negative energy is measured.  
The output frequency may be calculated using the following  
formula:  
Output Mode (OMODE)  
The output behavior of the SA2007H is selectable between  
fixed width outputs or latched outputs. In fixed width mode the  
P1 and P2 output pulses stay at a fixed width. In latched mode  
the status of P1 and P2 are cleared with a logic 1 on the RP pin.  
2
f = 11.16 x FOUT x ( I x I ) / I  
R
I
V
Where:  
FOUT= Typical rated output frequency (1360Hz)  
Refer to the “Output signals in latched mode” section (Page 6)  
for further information.  
I
I
I
=
=
=
Input current on current sense input (16µA at rated  
conditions)  
Input current on voltage sense input (14µA at rated  
conditions)  
I
Description  
OMODE  
V
0
Fixed width mode  
ReferencecurrentonVREFtypically50µA  
R
Latched mode  
1
An integrated anti-creep function does not allow output pulses  
onP1orP2ifnopowerismeasuredbythedevice.  
Clear Interrupt (RP)  
A logic 1 on the RP input is used to clear the interrupt  
generated by the SA2007H when a pulse is generated on P1  
or P2, while operating in latched mode. By clearing the  
interrupt in latched mode the status of the pulse outputs will  
also be cleared.  
v
MAINS  
t
Test Inputs (TEST, TCLK)  
For normal operations these pins must be connected to V .  
SS  
POWER  
V x I  
t
FOUT  
t
DR-01282  
t
P
Figure 4: FOUT instantaneous pulse output  
Direction indication (D1, D2)  
The SA2007H provides information about the energy flow  
direction of both current channels separately on pins D1 and  
D2.  
Logic 0 on pin D1 or D2 indicates reverse energy flow of that  
particular channel. Reverse energy flow is defined as the  
condition where the voltage sense input and current sense  
input are out of phase (greater than 90 degrees).  
5/10  
http://www.sames.co.za  
PRELIMINARY