SA2007H  
ssaammeess  
PIN DESCRIPTION  
Designation  
PIN  
Description  
Analog Ground. The voltage to this pin should be mid-way between V and V .  
SS  
20  
AGND  
DD  
Positive supply voltage. The voltage to this pin is typically +2.5V if a shunt resistor is used for  
current sensing or in the case of a current transformer a +5V supply can be applied.  
V
DD  
8
Negative supply voltage. The voltage to this pin is typically -2.5V if a shunt resistor is used for  
current sensing or in the case of a current transformer a 0V supply can be applied.  
V
SS  
14  
Analog Input for Voltage. The current into the A/D converter should be set at 14µA at  
RMS  
19  
IVP  
nominal mains voltage. The voltage sense input saturates at an input current of ±25µA peak.  
Inputs for current sensor - Channel 1 and Channel 2. The shunt resistor voltage from each  
1, 2,  
3, 4  
IIN1, IIP1  
IIN2, IIP2  
channel is converted to a current of 16µA at rated conditions. The current sense input  
RMS  
saturates at an input current of ±25µA peak.  
This pin provides the connection for the reference current setting resistor. A 24kW resistor  
5
VREF  
connected to V sets the optimum operating condition.  
SS  
This logic input is used to select between latched or unlatched condition for the pulse and  
direction outputs.  
6
7
9
OMODE  
RP  
A logic input is used to reset the latched outputs which is required after an interrupt has  
occurred.  
FMO  
The zero crossover of the voltage sense input is signaled on this pin.  
Configure / Test inputs. For normal operations these pins must be connected to V .  
SS  
10, 15  
12  
TCLK, TEST  
INT  
This logic output will indicate a change in status of the pulse or direction outputs.  
Pulse outputs. The P1 and P2 outputs give instantaneous pulse outputs of channel 1 and  
channel 2 respectively. The pulse is active low with a pulse width of 71.5µs for positive energy  
and doubles for reverse energy.  
17, 13  
P1, P2  
D1, D2  
NC  
Direction output. These outputs indicate the energy flow direction of each channel.  
No Connection.  
18, 16  
11  
ORDERING INFORMATION  
IIN1  
IIP1  
1
20 AGND  
Part Number  
SA2007HPA  
SA2007HSA  
Package  
DIP-20  
IVP  
2
19  
IIN2  
IIP2  
3
18 D1  
SOIC-20  
P1  
17  
4
VREF  
OMODE  
RP  
D2  
5
16  
15  
14  
13  
12  
11  
TEST  
6
VSS  
7
VDD  
P2  
8
INT  
FMO  
9
TCLK  
NC  
10  
DR-01620  
Figure 2: Pin connections: Package: DIP-20, SOIC-20  