SA2007H  
ssaammeess  
Interrupt (INT)  
Positive energy flow, when voltage sense and both current  
While the SA2007H is operating in latched mode (see Output  
mode description) an interrupt is generated with the falling  
edge of the pulse outputs P1 and P2 (see figure 7). INT is  
cleared with a logic 1 on the RP input.  
sense input are in phase, is indicated on pin D1 or D2 as a logic  
1.  
Figure 5 shows the behavior of D1 and D2, when energy  
reversal takes place. The time period for the direction signal to  
OUTPUT SIGNALS IN LATCHED MODE  
change state, t , is the time it takes for the internal integrator  
DIR  
Latched mode is selected by setting the OMODE input to logic  
1. This mode is used with a micro controller to ensure that any  
simultaneous pulses on P1 and P2 are not missed. The  
functionality of the latched mode is shown in figure 7.  
to count (down) from its present value to zero. Thus the energy  
consumption rate determines the speed of change on the  
direction outputs.  
An interrupt is generated with a falling edge on any of the pulse  
output signals P1 and P2. The micro controller needs to scan  
the status of the pulse outputs as well as the direction signals  
D1 and D2 during its interrupt service routine. The micro  
controller clears the interrupt by setting the RP input to a logic  
1. The pulse outputs P1 and P2 are cleared along with the  
interrupt. Note that energy pulses are inhibited when the  
interrupt output is set (during latched mode).  
I
t
V
t
FMO  
D1, D2  
t
DR-01283  
P1  
t
DIR  
Figure 5: Measured energy direction on D1 or D2  
P2  
Mains zero crossing indication (FMO)  
INT  
The square wave signal of FMO indicates the polarity of the  
mains voltage. Due to comparator offsets, the FMO low to high  
transition can occur within a range as shown in figure 6. The  
time between successive low to high transitions will be equal to  
the mains voltage period.  
RP  
dr-01621  
Figure 7: Output signals in latched mode  
V
t
FMO  
t
t
MAINS  
DR-01284  
Figure 6: Mains zero crossing on FMO  
6/10  
http://www.sames.co.za  