欢迎访问ic37.com |
会员登录 免费注册
发布采购

SA2007H 参数 Datasheet PDF下载

SA2007H图片预览
型号: SA2007H
PDF下载: 下载PDF文件 查看货源
内容描述: 单相双向双单元功率/电能计量IC,具有脉冲输出 [Single Phase Bidirectional Dual Element Power/Energy Metering IC with Pulse Output]
分类和应用: 脉冲
文件页数/大小: 10 页 / 156 K
品牌: SAMES [ SAMES ]
 浏览型号SA2007H的Datasheet PDF文件第1页浏览型号SA2007H的Datasheet PDF文件第3页浏览型号SA2007H的Datasheet PDF文件第4页浏览型号SA2007H的Datasheet PDF文件第5页浏览型号SA2007H的Datasheet PDF文件第6页浏览型号SA2007H的Datasheet PDF文件第7页浏览型号SA2007H的Datasheet PDF文件第8页浏览型号SA2007H的Datasheet PDF文件第9页  
SA2007H
ELECTRICAL CHARACTERISTICS
(V
DD
= 2.5V, V
SS
= -2.5V, over the temperature range -10°C to +70°C
#
, unless otherwise specified.)
Parameter
Operating temp. Range
Supply Voltage: Positive
Supply Voltage: Negative
Supply Current: Positive
Supply Current: Negative
Current Sensor Inputs (Differential)
Input Current Range
Voltage Sensor Input (Asymmetrical)
Input Current Range
Pin VREF
Ref. Current
Ref. Voltage
Digital I/O
Pins P1, P2, D1, D2, FMO, INT
Output High Voltage
Output Low Voltage
Pins TCLK, TEST, OMODE, RP
Input High Voltage
Input Low Voltage
Pulse Rate P1, P2
V
OH
V
OL
V
IH
V
IL
f
p
V
DD
-1
V
V
V
V
Hz
Hz
Hz
µs
µs
µA
I
IV
-I
R
V
R
-25
45
1.1
50
+25
55
1.3
µA
µA
V
I
II
-25
+25
µA
Symbol
T
O
V
DD
V
SS
I
DD
I
SS
Min
-25
2.25
-2.75
5
5
Typ
Max
+85
2.75
-2.25
6
6
Unit
°C
V
V
mA
mA
sames
Condition
Peak value
Peak value
With R = 24kW
connected to V
SS
Reference to V
SS
V
SS
+1
I
OH
= -2mA
I
OL
= 5mA
V
DD
-1
1360
5
0
71.55
143.1
48
V
SS
+1
1600
3000
At rated input conditions
Specified linearity
Min and Max frequency
Positive energy flow
Negative energy
V
1 =
V
DD
Pulse Width P1, P2
t
pp
t
pn
I
IL
Pins TCLK, TEST, RP, OMODE
Pull down current
110
#Extended Operating Temperature Range available on request.
ABSOLUTE MAXIMUM RATINGS*
Parameter
Supply Voltage
Current on any pin
Storage Temperature
Operating Temperature
Symbol
V
DD
-V
SS
I
PIN
T
STG
T
O
Min
-0.3
-150
-40
-25
Max
6.0
+150
+125
+85
Unit
V
mA
°C
°C
*Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress
rating only. Functional operation of the device at these or any other condition above those indicated in the operational sections of
this specification, is not implied. Exposure to Absolute Maximum Ratings for extended periods may affect device reliability.
2/10
PRELIMINARY