欢迎访问ic37.com |
会员登录 免费注册
发布采购

SA2002HSA 参数 Datasheet PDF下载

SA2002HSA图片预览
型号: SA2002HSA
PDF下载: 下载PDF文件 查看货源
内容描述: 单相双向功率/电能计量IC,具有瞬时脉冲输出 [Single Phase Bi-directional Power / Energy Metering IC with Instantaneous Pulse Output]
分类和应用: 脉冲
文件页数/大小: 12 页 / 149 K
品牌: SAMES [ SAMES ]
 浏览型号SA2002HSA的Datasheet PDF文件第1页浏览型号SA2002HSA的Datasheet PDF文件第3页浏览型号SA2002HSA的Datasheet PDF文件第4页浏览型号SA2002HSA的Datasheet PDF文件第5页浏览型号SA2002HSA的Datasheet PDF文件第6页浏览型号SA2002HSA的Datasheet PDF文件第7页浏览型号SA2002HSA的Datasheet PDF文件第8页浏览型号SA2002HSA的Datasheet PDF文件第9页  
SA2002H  
ssaammeess  
ELECTRICAL CHARACTERISTICS  
#
(V = 2.5V, V = -2.5V, over the temperature range -10°C to +70°C , unless otherwise specified.)  
SS  
DD  
Symbol  
Typ  
Parameter  
Min  
Max  
Unit  
Condition  
Operating temp. Range  
T
-25  
+85  
2.75  
-2.25  
5
°C  
V
O
Supply Voltage: Positive  
Supply Voltage: Negative  
Supply Current: Positive  
Supply Current: Negative  
Current Sensor Inputs (Diffferential)  
V
DD  
2.25  
-2.75  
V
SS  
V
I
DD  
3
3
mA  
mA  
I
SS  
5
Input Current Range  
I
II  
µA  
-25  
+25  
Peak value  
Voltage Sensor Input (Asymmetrical)  
I
IV  
µA  
-25  
+25  
Peak value  
Input Current Range  
Pin FOUT, FMO, DIR  
Output High Voltage  
Output Low Voltage  
V
V
V -1  
DD  
V
V
OL  
V +1  
SS  
OH  
f
p
1360  
Hz  
Hz  
Hz  
At rated input conditions  
Specified linearity  
Pulse Rate FOUT  
5
0
1600  
3000  
Min and Max frequency  
Pulse Width FOUT  
t
pp  
µs  
µs  
Positive energy flow  
Negative energy flow  
71.55  
143.1  
t
pn  
With R = 24kW  
Pin VREF  
-I  
µA  
V
connected to V  
Ref. Current  
Ref. Voltage  
45  
50  
55  
R
SS  
V
1.1  
1.3  
Reference to V  
R
SS  
# Extended Operating Temperature Range available on request.  
ABSOLUTEMAXIMUMRATINGS*  
Parameter  
Symbol  
Min  
Max  
Unit  
V
mA  
°C  
Supply Voltage  
V -V  
DD  
-0.3  
-150  
-40  
6.0  
SS  
Currentonanypin  
StorageTemperature  
OperatingTemperature  
I
PIN  
+150  
+125  
+85  
T
T
STG  
-25  
°C  
O
*Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress  
rating only. Functional operation of the device at these or any other condition above those indicated in the operational sections of  
this specification, is not implied. Exposure to Absolute Maximum Ratings for extended periods may affect device reliability.  
2/12  
3
http://www.sames.co.za