PM9603AP
ELECTRICAL CHARACTERISTICS
(Over the temperature range -10°C to +70°C, unless otherwise specified. Power
consumption figures are applicable to the PM9603APE only.)
Parameter
Symbol Min
Typ Max
Unit Condition
Supply Voltage
(Continuous)
VAC
180
90
230
115
265
135
V
V
PM9603APE
PM9603APA
Power Measurement
range
PRNG
-18400
18400
W
Specified
accuracy
Power Consumption1
800
mW
VAC = 230V
Supply direct
from mains
Isolation Voltage2
VIS
IO
2500
10
V
Continuous
Opto-coupler Output
Current
mA
mA
VOL = 1V
Opto-coupler Input
Current
II
10
Note 1: Power consumption specifications exclude power consumed by the current
sensor.
Note 2: Isolation voltage may be specified, depending on customer requirements.
CONNECTION DESCRIPTION
Designation
MAINS
Description
Voltage supply connection to Neutral line
Voltage supply connection to Live line
Connection to positive side of current sensor
NEUTRAL IN
NEUTRAL OUT Connection to negative side of current sensor
SK1
25-Way female
(D-type)
P1 Supply (+ve) to opto-couplers
P2 Input SA9603B - SCK
P8 Input SA9603B - DI
P9 Input SA9603B - CS
P12 Output SA9603B - DO
P18, 20-25 Common emitters and cathodes opto-couplers
3/18
sames