PM9603AP
BLOCK DIAGRAM
N E U T R AL
N E U T R AL
IN
S H U N T
O U T
O P T O -
C O U P L E R
S A 9 6 0 3 B
N E U T R AL
IN
P O W E R
M E T E R
W IT H
P O W E R
S U P P L Y
S P I B U S
L IV E
O P T O -
C O U P L E R
V O L T A G E S E N S E
D R -0 1 3 4 9
ABSOLUTE MAXIMUM RATINGS*
Parameter
Symbol
Min
Max
300
+2.5
Unit
V
V
°C
°C
A
Supply Voltage (Note 1)
Current Sense Input (Note 1)
Storage Temperature
Operating Temperature
Max Current
VAC
VIV
TSTG
TO
-2.5
-25
-10
+125
+70 (Note 2)
800 (Note 3)
2000 (Note 4)
IMAX
IMAX
through Sensor
A
Note 1: Voltages are specified with reference to Live.
Note 2: The SA9603B integrated circuit is specified to operate over the temperature
range -10°C to +70°C. The module functionality will however depend upon the
external components used.
Note 3: t = 500ms
Note 4: t = 1ms
*Stresses above those listed under “Absolute Maximum Ratings” may cause permanent
damage to the device. This is a stress rating only. Functional operation of the device
at these or any other conditions above those indicated in the operational sections of this
specification, is not implied. Exposure to Absolute Maximum Ratings for extended
periods may affect device reliability.
2/18
sames