RT5112A  
Sequence (7 slots)  
Note :  
Registers 0x00[6:4]/ 0x06[6:4] are used to control  
Buck1/Buck2 sequence on/off slot.  
(1) Any changes in Sequence (7 slots), slot interval  
time and soft-start time during sequence on or off  
procedure is not valid and will not modify the RT5112A  
setting.  
Registers 0x01[6:4], 0x02[6:4], 0x03[6:4] and  
0x04[6:4] are used to control LDOs sequence on/off  
slots.  
(2) Channel setting (output voltage, current limit...etc.)  
is fixed during on or off sequence.  
Slot Interval Time  
Register 0x09[7:6] is used to control interval time  
between each slot.  
(3) Register 0x09[5:4] = 11 will turn off all channels  
immediately.  
Soft Start Time  
(4) HWEN= 0 will turn off all channels and the RT5112A  
enters into power down mode.  
Register 0x09[7:6] is used to control Bucks sequence  
on soft start time.  
Normal Control Setting  
Register 0x11[1:0] is used to control LDOs sequence  
on soft start time.  
When register bits 0x09[5:4] = 10, the Bucks and LDOs  
on/off control depends on channel Enable bit.  
Sequence Control  
Registers 0x00[7]/0x06[7] are used to control Bucks  
on/off.  
Register 0x09[5:4] = 00 is used to enable sequence  
off with sequence setting 000.  
Register 0x01[7], 0x02[7], 0x03[7] and 0x04[7] are  
used to control LDOs on/off.  
Register 0x09[5:4] = 01 is used to enable sequence  
on with sequence setting000.  
HWEN  
BUCK1_DELAY  
LDOX_DELAY  
SEQ_CTRL = 10  
SEQ_CTRL = 01  
SEQ_CTRL = 00  
SLOT1  
SLOT2  
SLOT3  
SLOT4  
SLOT5  
SLOT6  
SLOT7  
SLOT7  
SLOT6  
SLOT5  
SLOT4  
SLOT3  
SLOT2  
SLOT1  
BUCK1  
LDO1  
LDO2  
LDO3  
LDO4  
Figure 1.  
Example for sequence on/off with BUCK1 assign to SLOT1, LDO1 assign to SLOT2, LDO2 assign to SLOT3, LDO3  
assign to SLOT4 and LDO4 assign to SLOT5.  
Copyright 2019 Richtek Technology Corporation. All rights reserved.  
©
is a registered trademark of Richtek Technology Corporation.  
DS5112A-02 August 2019  
www.richtek.com  
23  